Facing Material; Doors - Heat & Glo ESC-42ST Owner's Manual

Installation and operation
Hide thumbs Also See for ESC-42ST:
Table of Contents

Advertisement

23 IN.
3-1/2 IN.
NO COMBUSTIBLES
IN THIS AREA
39 IN.
4 IN.
Figure 13.5
B. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or fi nishing materials must not interfere with
air fl ow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or fi nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
COMBUSTIBLE MATERIAL
0 in.
NON-COMBUSTIBLE
Figure 13.6 Noncombustible Facing Diagram
1/2 IN. BUILDING MATERIAL
(MAY BE COMBUSTIBLE)
COMBUSTIBLE
FRAMING
FACTORY-
SUPPLIED 1/2 IN.
NON-
COMBUSTIBLE
BOARD
61-5/8 in.
0 in.
0 in.
47-1/8 in.
BOARD
Heat & Glo • ESC-42ST • 2146-900 Rev. Q • 4/13
C. Doors
Only doors certifi ed for use with this appliance model may
be used. Contact your dealer for a list of doors that may
be used. Once you have determined what kind of door
and fi nishing material is going to be used on the fi replace,
you may use the table below which shows the door mod-
els and the fi nishing material thickness allowed.
FS-E42-XX
FSA-ESC42ST-XX
(REQUIRES ARCHKIT-ESC-42ST)
Figure 13.7 Approved Doors for ESC-42ST
Note: Optional fi rescreen sits out 1-1/2 inches from the face
of the fi replace. When using thin fi nishing material, you may
want to use thicker non-combustible backer board to bring
the fi nishing material fl ush with the fi rescreen. This is not
required.
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents