D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing or fi nishing material closer than
the minimums listed must be constructed entirely of non-
combustible materials (i.e., steel studs, concrete board, etc).
Failure to comply could cause fi re.
Combustible Mantels
12 IN.
MAX.
10 IN.
MIN.
FIREPLACE
OPENING
Figure 5.3 Clearances to mantels or other combustibles
above appliance
Non-combustible Mantels
12 IN.
MAX.
10 IN.
MIN.
NON-COMBUSTIBLE
MATERIAL
FIREPLACE
OPENING
Figure 5.4 Clearances to Mantels or other Non-Combustibles
Above Appliance
4 IN.
MAX.
Heat & Glo • ESC-42ST • 2146-900 Rev. Q • 4/13
Combustible Mantel Legs or Wall Projections
FIREPLACE
OPENING
6 IN.
MAX.
6 IN. MIN. FROM
OPENING
13 IN. MIN.
FROM OPENING
Figure 5.5 Clearances to Combustible Mantel Legs or Wall
Projections.
Non-Combustible Mantel Legs or Wall Projections
FIREPLACE
OPENING
NON-COMBUSTIBLE
4 IN. MAX.
MANTEL LEG
13 IN. MIN.
Figure 5.6 Clearances to Non-Combustible Mantel Legs or
Wall Projections.
1 IN. MIN.
COMBUSTIBLE
MATERIAL
7 IN.
COMBUSTIBLE WALL OR
MANTEL LEG
1 IN. MIN.
NON-COMBUSTIBLE WALL
21