Heat & Glo ESC-42ST Owner's Manual page 29

Installation and operation
Hide thumbs Also See for ESC-42ST:
Table of Contents

Advertisement

2. Top Vent - Vertical Termination
No Elbow
Note: Flue restrictor is permit-
ted ONLY on 30 ft. minimum
vertical runs with no elbows.
Note: Must have a 24 inches minimum
vertical vent before attaching any
elbow to the appliance.
Figure 7.6
Note: Flue restrictor is permit-
ted ONLY on 30 ft. minimum
vertical runs with no elbows.
Note: Must have a 24 inches minimum
vertical vent before attaching any
elbow to the appliance.
Figure 7.7
V
1
Heat & Glo • ESC-42ST • 2146-900 Rev. Q • 4/13
V
= 50 ft. Max. (15.2 m)
1
V
= 3 ft. Min. (914 mm)
1
FLUE RESTRICTOR
NOTE: Flue Restrictor ships in
manual bag assembly.
V
1
2 ft
610 mm
1 ft
3 ft
914 mm
3 ft
4 ft
1.2 m
4 ft
5 ft
1.5 m
9 ft
6 ft
1.8 m
12 ft
V
+ V
+ H
= 50 ft (15.2 m) Max.
1
2
1
*No specifi c restrictions on this value EXCEPT
V
+ V
+ H
cannot exceed 60 ft (18.3 m).
1
2
1
After V
= 6 ft, then H
1
1
H
V
1
2
305 mm
*
914 mm
*
1.2 m
*
2.7 m
*
3.7 m
*
Max.= V
x 2
1
29