Performance
Data Sheet
Smart Water Filtration
System
GSWF Cartridge
This system
has been tested according
to NSF/ANS142/53
for reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water
entering
the system
was reduced
to a concentration
less than or equal
to the permissible
limit for water leaving
the system,
as specified
in NSF/ANS142/53.
*
(700% safety fbctors built in for unmetered
usage)
Standard
No. 42: Aesthetic
Effects
Parameter
[nfluent Challenge
Effluent
Average
> 97.29%
Chlorine
T&O
--
--
Particulate**
99.98%
99.91%
Parameter
USEPA
[nfluent
MCL
Average
--
1.845mg/L
--
143,333 #/mL
USEPA
MCL
1 NTU***
99.95% Reduction
0.015 mg/L
0.015 mg/L
0.0002 mg/L
0.003 mg/L
Concentration
Average
2.0 mg/L_+lO%
< 0.05 mg/L
at leas1 10,000 partic[es/ml
29.83 #/mL
Standard
No. 53: Health
Effects
[nfluent
Average
10.3 NTU***
200,000 #/L
0.15 mg/L
0.14 mg/L
0.0216 mg/L
0.008 mg/L
Influent Challenge
Concentration
1+1 NTU***
Minimum 50,000 [
0.15 mg/L_+lO%
0.15 mg/L_+lO%
0.002 mg/L_+lO%
0.009 mg/L+l 0%
Effluent
Average
0.106 NTU
0
< 0.001 mg/L
0.001 mg/L
< 0.00002 mg/L
< 0.002 mg/L
Maximum
0.05mg/L
140#/mL
Maximum
0.14 NTU
0
< 0.001 mg/L
0.003 mg/L
< 0.00002 mg/L
< 0.002 mg/L
Turbidity
Cysts
Lead at pH 6.5
Lead at pH 8.5
Lindane
Atrazine
% Reduction
Minimum
96.43%
% Reduction
Average
Minimum
98.97%
98.61%
> 99.99%
> 99.99%
> 99.33%
> 99.33%
> 99.29%
97.86%
99.07%
98.75%
> 76.12%
> 66.67%
* Tested using a flow rate of (15 gpm; pressure
of 60 psig; pH of Z 5 + O, 5 ; temp, of 68 _"+ 5_F (20 _"+ 3 _'C)
** Measurement
in Particles/ml,
Particles used were O, 5 - 7 microns
*** NTU Nephelometric
Turbidity units
Operating
Specifications
[] Capacity: certified for up to 750 gallons (2,838 I); up to six months
[] Pressure requirement:
40-120
psi (2,8-8,2 bar)
[] Temperature:
33-100°F
(0,6-38°C)
[] Flow rate: 0,5 gpm (1,9 Ipm)
General
Installation/Operation/Maintenance
Requirements
[] Run 11/2gallons at full flow to purge out trapped
air,
[] Replace cartridge
when flow becomes
too slow,
Min. Required
Reduction
_>50%
_>85%
Min. Required
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/L
0,0002 mg/L
0,003 mg/L
Special
Notices
[] Installation
instructions,
parts and service availability,
and standard
warranty
are included with the product when shipped,
[] This drinking water
system must be maintained
according
to manufacturer's
instructions,
including
replacement
of filter
cartridges,
[] Do not use with water that is microbiologically
unsafe or of unknown
quality without
adequate
disinfection
before or after the
system, Systems certified
for cyst reduction
may be used on disinfected
water that may contain filterable
cysts,
[] The contaminants
or other substances
removed
or reduced
by this water treatment
system are not necessarily
in your water,
[] Check for compliance
with the state and local laws and regulations,
[] Note that while the testing
was performed
under standard
laboratory
conditions,
actual performance
may vary, Systems
must be installed
and operated
in accordance
with manufacturer's
recommended
procedures
and guidelines,
System
tested
and certified
by NSF International
against
Standard
42 for the reduction
of
chlorine,
taste
and odor, particulate
Class I and Standard
53 for the reduction
of cyst, lead,
Lindane,
Atrazine
and turbidity,
Manufactured
for: General
Electric
Company,
Louisville,
KY 40225
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gth18ibdbrbbGth18ibdbrww

Table of Contents