Appendix D.3. Error Codes - FieldServer FS-8704-14 Driver Manual

Ethernet/ip
Hide thumbs Also See for FS-8704-14:
Table of Contents

Advertisement

FS-8704-14 EtherNet/IP Manual

Appendix D.3. Error Codes

General
Extended
Status
Status
0x01
0x0100
0x01
0x0103
0x01
0x0106
0x01
0x0107
0x01
0x0108
0x01
0x0109
0x01
0110
0x01
0x0111
0x01
0x0113
0x01
0x0114
0x01
0x0115
0x01
0x0116
0x01
0x0117
0x01
0x0118
0x01
0x0119
0x01
0x011A
0x01
0x011B
0x01
0x0203
0x01
0x0204
0x01
0x0205
0x01
0x0206
0x01
0x0207
0x01
0x0301
0x01
0x0302
0x01
0x0303
0x01
0x0304
0x01
0x0311
0x01
0x0312
0x01
0x0315
0x01
0x0316
0x01
0x0317
0x01
0x0318
0x01
0x0319
0x01
0x031A
0x01
0x031B
0x01
0x031C
0x01
0x031D
0x01
0x031D
0x01
0x031E
0x01
0x0320-
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
Description
Connection in Use or Duplicate Forward Open.
Transport Class and Trigger combination not supported
Ownership conflict
Connection not found at target application.
Invalid Connection Type. Indicates a problem with either the Connection Type or
Priority of the Connection.
Invalid connection size
Device not configured
RPI not supported. May also indicate problem with connection time-out multiplier
or production inhibit time.
Connection Manager cannot support any more connections
Either the Vendor Id or the Product Code in the key segment did not match the
device
Product Type in the key segment did not match the device
Major or Minor Revision information in the key segment did not match the device
Invalid Connection Point
Invalid Configuration Format
Connection request fails since there is no controlling connection currently open.
Target Application cannot support any more connections
RPI is smaller than the Production Inhibit Time
Connection cannot be closed since the connection has timed out
Unconnected Send timed out waiting for a response.
Parameter Error in Unconnected Send Service
Message too large for Unconnected message service
Unconnected acknowledge without reply
No buffer memory available
Network Bandwidth not available for data
No Tag filters available
Not Configured to send real-time data
Specified Port Not Available – the FieldServer is trying to open a connection but
the target port is not available at the remote device. This can be resolved by using
the correct EIP_Path parameter.
Link Address specified in Port Segment Not Available
Invalid Segment Type or Segment Value in Path
Path and Connection not equal in close
Either Segment not present or Encoded Value in Network Segment is invalid.
Link Address to Self Invalid
Resources on Secondary Unavailable
Connection already established
Direct connection already established
Miscellaneous
Redundant connection mismatch
No more consumer resources available in the producing module
No connection resources exist for target path
Vendor Specific
Page 29 of 30