(Supplement to the FieldServer Instruction Manual)
FS-8704-07 ALLEN BRADLEY PCCC (TCP/IP)
APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after February 2012
Driver Manual
Driver Version:
Document Revision:
A Sierra Monitor Company
1.00
9

Advertisement

Table of Contents
loading

Summary of Contents for FieldServer FS-8704-07

  • Page 1 Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8704-07 ALLEN BRADLEY PCCC (TCP/IP) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after February 2012 A Sierra Monitor Company Driver Version: 1.00 Document Revision:...
  • Page 2: Table Of Contents

    Appendix C.1. Command Support ... 15 Appendix C.2. Error Messages ... 15 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Table of Contents...
  • Page 3: Allen Bradley Allen Bradley Pccc (Tcp/Ip) Description

    FS-8704-07 Allen Bradley PCCC (TCP/IP) Driver Manual ALLEN BRADLEY ALLEN BRADLEY PCCC (TCP/IP) DESCRIPTION The Allen Bradley PCCC (TCP/IP) driver allows the FieldServer to transfer data to and from devices over Allen Bradley PCCC (TCP/IP) Ethernet protocol. The FieldServer can emulate either a Server or Client.
  • Page 4: Hardware Connections

    HARDWARE CONNECTIONS Make sure the device IP_address is configured to be on the same IP network as the FieldServer. Use a crossover cable if the FieldServer is connected directly to the PLC device. Use a straight cable if the FieldServer is connected to a hub.
  • Page 5: Data Array Parameters

    DA_DI_01 , Bit DA_DO_01 , Bit FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com , Data_Array_Length , 200 , 200 , 200...
  • Page 6: Configuring The Fieldserver As A Allen Bradley Pccc (Tcp/Ip) Client

    Allen Bradley PCCC (TCP/IP) Server. The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for Allen Bradley PCCC (TCP/IP) communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays”...
  • Page 7: Client Side Node Descriptors

    , Node_ID , Protocol PLC_01 , AB_CSP FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com , PLC_Type , IP_Address , Adapter , SLC5 , 192.168.1.13...
  • Page 8: Client Side Map Descriptors Client Side Map Descriptors

    Other device might not be supporting the full range, e.g. SLC5 supports only 0-255 and latest PLC5 till now supports only 0-1999 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 8 of 15...
  • Page 9: Map Descriptor Example

    "Other device might not be supporting the full range, e.g. SLC5 supports only 0-255 and latest PLC5 till now supports only 0-1999" FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 9 of 15...
  • Page 10: Configuring The Fieldserver As An Allen Bradley Pccc (Tcp/Ip) Server

    ABE_Srv_11 , 11 , AB_CSP FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Legal Values Up to 32 alphanumeric characters 0-255 AB_CSP, AB_TCP...
  • Page 11: Server Side Map Descriptors

    Other device might not be supporting the full range, e.g. SLC5 supports only 0-255 and latest PLC5 till now supports only 0-1999 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 11 of 15...
  • Page 12: Map Descriptor Example

    , DA_DO_01 , Passive FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 12 of 15 , ABE_Srv_11 , N , 10...
  • Page 13: Appendix A. Troubleshooting

    Server map 1: N21: 0-31 Server map 2: N21: 32-100 This will panic the FieldServer and crash RS view as the DH+ will attempt to map N21: 0-100. If set up as Server Map 1: N21: 0-100, no problems are experienced.
  • Page 14: Appendix B. Vendor Information

    Press "Display Station Browser" icon  See that your device is discovered Task Complete FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 14 of 15...
  • Page 15: Appendix C. Reference

    This message is typically printed when the remote AB_TCP node is not connected to the begins.. network or is unreachable. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 15 of 15 Typical Write...