Appendix C.3.3. Minor Error Status Codes: Program Load And Store Requests - FieldServer FS-8700-66 Driver Manual

Ge snp driver
Hide thumbs Also See for FS-8700-66:
Table of Contents

Advertisement

FS-8700-66 GE-SNP Driver Manual
Decimal
Hex
Description
-55
0C9
Login using non-zero buffer size required for block commands.
-56
0C8
Password(s) already enabled and cannot be forced inactive.
-57
0C7
Passwords are set to inactive and cannot be enabled or disabled.
-58
0C6
Control Program (CP) tasks exist but requestor not logged into main CP.
-59
0C5
No task-level Rack/Slot configuration to read or delete.
-60
0C4
Verify with FA Card or EEPROM failed.
-61
0C3
Text length does not match traffic type.
-62
0C2
The OEM key is NULL (inactive).
-63
0C1
Invalid block state transition.
-64
0C0
Bad OMF record checksum in store.
-65
0BF
Illegal OMF record type/data contents.
-66
0B
Bad Block Type given in Load/Store.
-67
0BD
Block Set (subblock name) not found.
-68
0BC
Block Type (e.g., data) not found.
-69
0B
Maximum length of a partial store exceeded.
-70
0B
Block Set already exists, cannot create.
-71
0B9
Executable flag in TYPDEF record not set.
-72
0B8
Size of the Segment Selector Table in TYPDEF record is not correct.
-73
0B7
Segment length in Verify not equal to the segment length of block in the PLC.
-74
0B6
Cyclic Redundancy Check (CRC) checksum comparison in Verify failed.
-75
0B5
Additive checksum comparison in Verify failed.
-76
0B4
Attempt to alter interrupt list in MAIN DECL BLOCK during RUN MODE.
-77
0B3
Length limit exceeded; includes read past end of transferred data, writes past ofprogram block.
-78
0B2
Program block already exists and cannot be replaced.
Appendix C.3.3.
Minor Error Status Codes: Program Load and Store Requests
Decimal,
Hex,
Description
80
50
Problem with sending mail to the slave Service Request task. (Series 90-70 PLC CPUs only).
81
51
Problem with getting mail from the slave Service Request task. (Series 90-70 PLC CPUs only).
85
55
Slave SNP task timed out before receiving SRP response. (Series 90-70 PLC CPUs only).
Slave SNP task could not find the requested Datagram connection. (Series 90-70 PLC CPUs
86
56
only).
Slave SNP task encountered an error in trying to write the Datagram. (Series 90-70 PLC CPUs
87
57
only).
Slave SNP task encountered an error in trying to update the Datagram. Series 90-70 PLC CPUs
88
58
only).