FieldServer FS-8700-72 Driver Manual

Secutron modul-r driver
Hide thumbs Also See for FS-8700-72:

Advertisement

(Supplement to the FieldServer Instruction Manual)
APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after March 2010
Driver Manual
FS-8700-72 Secutron
A Sierra Monitor Company
Driver Version:
1.02
Document Revision:
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FS-8700-72 and is the answer not in the manual?

Questions and answers

Summary of Contents for FieldServer FS-8700-72

  • Page 1 Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8700-72 Secutron APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after March 2010 A Sierra Monitor Company Driver Version: 1.02 Document Revision:...
  • Page 2: Table Of Contents

    Appendix B.2. Panel Circuit or Zone numbers ... 15 Appendix B.3. Panel Power-up, Restarts and Resets ... 16 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Table of Contents...
  • Page 3: Secutron Modul-R Driver Description

    FS-8700-72 Secutron Manual SECUTRON MODUL-R DRIVER DESCRIPTION The Secutron Modul-R driver allows the FieldServer to transfer data to and from a Client and a Server panel on a single point to point network over RS-232 using Secutron Modul-R protocol. The protocol is strictly command/response with the Client polling a Server device. A Server device can report the generation and clearing of alarms to the polling Client.
  • Page 4: Driver Scope Of Supply

    FieldServer Technologies PART # FS-8917-16 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Description Pigtail cable for RJ45 Port Page 4 of 16...
  • Page 5: Hardware Connections

    From RJ-45 To Secutron Brown White/Orange Blue/white FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Orange/White Blue/white Brown FieldServer Part # 8917-16...
  • Page 6: Data Array Parameters

    , Bit p1c90_function , Byte FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com , Data_Array_Length , 1000 , 1000 , 100...
  • Page 7: Configuring The Fieldserver As A Secutron Modul-R Driver Client

    This section documents and describes the parameters necessary for configuring the FieldServer to communicate with Secutron Modul-R panels. The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for Secutron Modul-R driver communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays”...
  • Page 8: Client Side Node Parameters

    Function Scan_Interval Rate at which data is polled FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com , Connection , P1 Legal Values...
  • Page 9: Map Descriptor Example

    OK FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 9 of 16 , Node_Name , Secutron_Type , Secutron_Circuit , Length...
  • Page 10: Configuring The Fieldserver As A Secutron Modul-R Driver Server

    FieldServer (See “.csv” files provided with the FieldServer). The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for Secutron Modul-R driver communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays”...
  • Page 11: Server Side Map Descriptors

    The number of devices on the circuit the Map Descriptor must represent FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com , Connection...
  • Page 12: Map Descriptor Example

    FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 12 of 16 , Data_Array_Offset , Function...
  • Page 13: Appendix A. Troubleshooting

    This is a useful configuration tool to ensure that all required data is stored. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com...
  • Page 14: Appendix B. Reference

    Supervisory Trouble or Parameter Change Wrong Device Type Waterflow Alarm FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 14 of 16...
  • Page 15: Appendix B.2. Panel Circuit Or Zone Numbers

    This is a useful configuration tool to ensure that all required data is stored. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com...
  • Page 16: Appendix B.3. Panel Power-Up, Restarts And Resets

    (Circuit 90) Function number of the Hot Key pressed. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Events 000 – Power On/Hard reboot 003 –...