Win_Avail_Always Y | N; Win_Avail_C11 Y | N; Wsinfo None | Query | Required | Match; Winscript_First Y | N - HP NonStop SSH 544701-014 Reference Manual

Table of Contents

Advertisement

WIN_AVAIL_ALWAYS Y | N

Controls availability of dedicated windows to connect to a new session. Default N means availability is determined by
WIN_AVAIL_C11. When set to Y, a DEDICATED window is always available for connection to a new remote session
request, even if there is no active open from any application to that window.

WIN_AVAIL_C11 Y | N

WIN_AVAIL_C11 Y | N , default Y. WIN_AVAIL_C11 determines availability of a window when a static service is
selected from STN02 menu, or a session attempts to connect to a dedicated window. With WIN_AVAIL_C11 Y, the
window is available if one (or more) control 11 requests are outstanding. With WIN_AVAIL_C11 N, the window is
available if the window has one (or more) application openers. If the window is available the session is connected to it; if
not, STN13 error message is displayed followed by a repeat of the STN02 service menu.

WSINFO NONE | QUERY | REQUIRED | MATCH

The command WSINFO requests workstation information using ESC-9e supported by the Win6530 and J6530 emulators
by comForte. The information fields HOST NAME, IP ADDRESS, and USER NAME are retrieved and displayed in the
STATUS SESSION command.
INFO STN displays the current WSINFO setting
The various values of WSINFO work as follows:
NONE
Nothing is sent to the workstation—this is default behavior.
QUERY
ESC-9e is sent to WS after the first response to the Service prompt (or at the equivalent time for TYPE DEDICATED
windows). STN will wait five seconds for a response. The response is included in a new AUDIT event and is shown by
STATUS SESS. The session always continues regardless of the response of even if no response is received.
REQUIRED
Like above, but a response is required. If none is received, the session is terminated with the following message
displayed on the Workstation for 10 seconds:
STN57 This 6530 emulator does not support required WSINFO.
MATCH
Like above, but in addition, the IPADDRESS in the response must match the network IP address from accept_nw, or the
session is terminated with the following message displayed on the Workstation for 10 seconds:
STN58 WSINFO address does not match network address.

WINSCRIPT_FIRST Y | N

Since release A74, all SSH windows are automatically configured with a SCRIPT PTY-SSH$. If this script was defined
by ADD SCRIPT, then the specified setmodes were performed, otherwise no setmodes were done. However, this did not
allow any script specified for a SERVICE to apply to SSH sessions.
WIN_SCRIPT_FIRST now allows SSH sessions to use the script defined for the selected service.
Y
The default for compatibility with B19 and earlier releases. SSH sessions either use script PTY-SSH$ if configured or if
PTY-SSH$ is not configured, then no script. Any script defined with the service used for the session is ignored.
N
SSH sessions use the script, if any, defined for the service. If none is defined, then the script defined for the window, if
any, is used; otherwise, no script. This allows SSH sessions to access STN services which specify their own scripts.