3) To prevent miswiring, check the terminal numbers and lead wire colors with the
Wiring Label.

[f] COMPRESSOR CAPACITOR - EXCEPT KM-61BAH

1) Disconnect the Tab Terminals and cut the Tie.
2) Install the new Capacitor in the reverse order of the removal procedure. Use a cable
tie to secure the Capacitor tightly.

[g] CONTROL BOARD TRANSFORMER

1) Disconnect the Connectors and Closed End Connectors connecting the Control
Board. (The Tie securing the harness may be removed. But be careful not to break
the lead wires.)
2) Remove the mounting screw and lift off the Transformer from the fi t at the bottom.
3) Install the new Transformer in the reverse order of the removal procedure.

19. WATER TANK

1) Unplug the icemaker or disconnect the power source. Remove all ice from the
Storage Bin.
2) Drain out the Water Tank by pulling off the Overflow Pipe from the Water Tank
bottom and the Silicone Hose from the Storage Bin bottom.
Cube Guide
Silicone Hose
(Connect/disconnect
arrowed part)
Storage Bin
Fig. 25
67
Water Tank
Overfl ow Pipe
(Disconnect from tank
bottom)