Hoshizaki KM-600MAH Instruction Manual
Hoshizaki KM-600MAH Instruction Manual

Hoshizaki KM-600MAH Instruction Manual

Modular crescent cuber
Hide thumbs Also See for KM-600MAH:

Advertisement

Quick Links

Hoshizaki
Hoshizaki America, Inc.
"A Superior Degree
of Reliability"
www.hoshizaki.com
Modular Crescent Cuber
Model
KM-600MAH
INSTRUCTION MANUAL
Issued: 6-24-2008
Revised: 3-31-2010

Advertisement

Table of Contents
loading

Summary of Contents for Hoshizaki KM-600MAH

  • Page 1 Hoshizaki Hoshizaki America, Inc. Modular Crescent Cuber Model KM-600MAH INSTRUCTION MANUAL “A Superior Degree of Reliability” www.hoshizaki.com ™ Issued: 6-24-2008 Revised: 3-31-2010...
  • Page 2 Should the reader have any questions or concerns which have not been satisfactorily addressed, please call, write, or send an e-mail message to the Hoshizaki Technical Support Department for assistance. HOSHIZAKI AMERICA, INC.
  • Page 3: Table Of Contents

    IMPORTANT This manual should be read carefully before the icemaker is installed and operated. Only qualified service technicians should install, service, and maintain the icemaker. Read the warnings contained in this booklet carefully as they give important information regarding safety. Please retain this booklet for any further reference that may be necessary.
  • Page 4: Important Safety Information

    Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit. WARNING Indicates a hazardous situation which could result in death or serious injury. CAUTION Indicates a situation which could result in damage to the unit.
  • Page 5: Specifications

    I. Specifications A. Nameplate Rating 1. KM-600MAH (air-cooled) HOSHIZAKI ICE MAKER MODEL NUMBER KM-600MAH SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 115-120V 10.3RLA 70LRA PUMP 120V 0.5FLA 10W 120V 1.0FLA 30W OTHER 115-120V 0.2A MAXIMUM FUSE SIZE 15 AMPS MAX. HACR BREAKER(USA ONLY) 15 AMPS MAX.
  • Page 6: Dimensions / Connections

    B. Dimensions / Connections 1. KM-600MAH...
  • Page 7: Installation And Operating Instructions

    • Check that the compressor is snug on all mounting pads. • See the nameplate on the rear panel, and check that your voltage supplied corresponds with the voltage specified on the nameplate. • This icemaker can be installed on a storage bin 22" wide or wider. Hoshizaki Ice Storage Bin, Model B-300 series is recommended. For further options, contact your local Hoshizaki distributor. B. How to Remove Panels See Fig. 1 • Front Panel: Remove the screw. Lift up and towards you. Insulation • Top Panel: Lift up at front slightly, push rearward,...
  • Page 8: Location

    C. Location CAUTION 1. This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating water temperature should be within 45°F to 90°F (7°C to 32°C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect icemaker performance.
  • Page 9: Electrical Connection

    E. Electrical Connection WARNING 1. Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or severe damage to equipment. 2.
  • Page 10: Water Supply And Drain Connections

    10 PSIG. Do not run the icemaker until the proper water pressure is reached. • A plumbing permit and services of a licensed plumber may be required in some areas. • External filters, strainers, or softeners may be required depending on water quality. Contact your local Hoshizaki distributor for recommendations. • Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required. • The icemaker and condensation drain line(s) and storage bin drain line must be run separately.
  • Page 11 • Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the icemaker water supply line. • An icemaker water supply line shut-off valve and drain valve should be installed. • Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" OD hard pipe is recommended for the icemaker drain line. Condensation drain outlet is 3/8" OD pipe. The condensation drain line can be connected to the icemaker drain line or can be run separately. KM-600MAH Icemaker Water Supply Line Shut-Off Valve Icemaker Icemaker Water Supply Inlet 1/2" FPT...
  • Page 12: Final Checklist

    G. Final Checklist WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the storage bin. 1) Is the icemaker level? 2) Is the icemaker in a site where the ambient temperature is within 45°F to 100°F (7°C to 38°C) and the water temperature within 45°F to 90°F (7°C to 32°C) all year around? 3) Is there at least 6" (15 cm) clearance at sides, rear, and top of the icemaker for proper air circulation and ease of maintenance and service?
  • Page 13: Startup

    H. Startup WARNING 1. All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty coverage. 2. If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor. 3.
  • Page 14: Cleaning And Maintenance

    A. Cleaning and Sanitizing Instructions Hoshizaki recommends cleaning and sanitizing this unit at least once a year. More frequent cleaning and sanitizing, however, may be required in some existing water conditions.
  • Page 15: Cleaning Procedure

    1. Cleaning Procedure 1) Dilute 16 fl. oz. (473 ml) of Hoshizaki "Scale Away" with 3 gal. (11 l) of warm water. 2) Remove all ice from the evaporator and the storage bin. Note: To remove cubes on the evaporator, turn off the power supply and turn it back on after 3 minutes. The harvest cycle starts and the cubes will be removed from the evaporator.
  • Page 16: Sanitizing Procedure - Following Cleaning Procedure

    22) Replace the front panel in its correct position. 23) Turn on the power supply to rinse off the cleaning solution. 24) Turn off the power supply after 5 minutes. 25) Remove the front panel. 26) Disconnect one end of the pump tubing to drain the water tank. After the water tank has drained, reconnect the pump tubing.
  • Page 17: Maintenance

    B. Maintenance This icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemaker. WARNING 1. Only qualified service technicians should attempt to service or maintain this icemaker. 2. Disconnect power before performing service or maintenance. 1.
  • Page 18: Preparing The Icemaker For Long Storage

    C. Preparing the Icemaker for Long Storage CAUTION 1. When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instructions below to prevent damage. 2. To prevent damage to the water pump seal, do not operate the icemaker with the control switch in the "WASH" position when the water tank is empty.
  • Page 19 HOSHIZAKI AMERICA, INC. 618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 91A1KQ10C...