Main Profile Parameters
NOTE:. Mark " " in b031=10 shows the accessible parameters when b031 is set "10", high
level access.
Func.
Name
Code
Output frequency setting
F001
Acceleration time (1)
F002
Acceleration time (1),
F202
nd
2
motor
Deceleration time (1)
F003
Deceleration time (1),
F203
nd
2
motor
Keypad RUN key routing
F004
"F" Function
Description
Standard default target frequency
that determines constant motor
speed, range is 0.0 / start
frequency to maximum frequency
(A004)
Standard default acceleration,
range is 0.01 to 3600 sec.
Standard default deceleration,
range is 0.01 to 3600 sec.
Two options; select codes:
00 ...Forward
01 ...Reverse
49
Run
Defaults
Mode
Lnitial data
Units
Edit
0.0
10.0
sec.
10.0
sec.
10.0
sec.
10.0
sec.
00
Hz