Hitachi WJ200 Series Quick Reference Manual page 34

Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

Multi-Speed Select ~Binary Operation
The inverter can store up to 16 different target
frequencies (speeds) that the motor output uses for
steady-state run condition. These speeds are accessible
through programming four of the intelligent terminals as
binary-encoded inputs CF1 to CF4 per the table to the
right. These can be any of the six inputs, and in any
order. You can use fewer inputs if you need eight or
fewer speeds.
NOTE: When choosing a subset of speeds to use,
always start at the top of the table, and with the
least-significant bit: CF1, CF2, etc.
Speed
3rd
7th
5th
2nd
1st
6th
4th
0th
1
[CF1]
0
1
[CF2]
0
1
[CF3]
0
1
[FW]
0
Option
Terminal
Code
Symbol
CF1
Multi-speed Select,
02
Bit 0 (LSB)
CF2
Multi-speed Select,
03
Bit 1
CF3
Multi-speed Select,
04
Bit 2
CF4
Multi-speed Select,
05
Bit 3 (MSB)
C001~C007
Valid for inputs:
F001, A001=02,
Required settings
A020
Notes:
When programming the multi-speed settings,
be sure to press the SET key each time and then
set the next multi-speed setting. Note that when
the key is not pressed, no data will be set.
When a multi-speed setting more than 50Hz
(60Hz) is to be set, it is necessary to program the
maximum frequency
A004
that speed
Function Name
State
ON
OFF
ON
OFF
ON
OFF
ON
OFF
to
A035
high enough to allow
Multi-
speed
Speed 0
Speed 1
Speed 2
Speed 3
Speed 4
Speed 5
Speed 6
Speed 7
Speed 8
Speed 9
Speed 10
Speed 11
Speed 12
Speed 13
Speed 14
Speed 15
The example with eight speeds in the
figure below shows how input switches
configured for CF1–CF3 functions can
change the motor speed in real time.
NOTE: Speed 0 depends on
parameter value.
Description
Binary encoded speed select, Bit 0, logical 1
Binary encoded speed select, Bit 0, logical 0
Binary encoded speed select, Bit 1, logical 1
Binary encoded speed select, Bit 1, logical 0
Binary encoded speed select, Bit 2, logical 1
Binary encoded speed select, Bit 2, logical 0
Binary encoded speed select, Bit 3, logical 1
Binary encoded speed select, Bit 3, logical 0
Example (some CF inputs require input
configuration; some are default inputs):
CF4 CF3 CF2 CF1
7
6
5
4
See I/O specs on
page 4–6.
32
Input Function
CF4 CF3 CF2 CF1
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
A001
3
2
1
L
P24
PCS
PLC