Download Print this page

Qlogic 3000 Series Reference Manual page 86

Fibre channel switch
Hide thumbs Also See for 3000 Series:

Advertisement

5–Indication Support Classes
Predefined Filters
Alert:Core12
Alert:FC1
Alert:FC2
Alert:FC5
Alert:FC6
Alert:FC7
Alert:FC8
5-8
CQL:SELECT * FROM CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID='Core12'
An indication will be thrown whenever a port has changed status. The
following port status changes are reported: unknown, other, Ok,
Degraded, Stressed, Predictive, Failure, Error, Non-Recoverable Error,
Starting.
CQL:SELECT * FROM CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID='FC1'
An indication will be thrown whenever the inactive zoning database
changes. As the CIMAgent doesn't support zoning sessions, this
means that a multi-step zoning change via CIM will result in multiple
indications.
CQL:SELECT * FROM CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID='FC2'
An indication will be thrown whenever a Zoneset is Activated
CQL:SELECT * FROM CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID='FC5'
An indication will be thrown whenever the switch status has changed.
Switch statuses represented in this indication are: Unknown, Ok,
Stopped, In Service.
CQL:SELECT * FROM CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID='FC6'
An indication will be thrown whenever the fabric state has been
changed status. Possible status changes are merged or segmented.
CQL:SELECT * FROM CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID='FC7'
An indication will be thrown whenever a switch has been added to the
fabric.
CQL:SELECT * FROM CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID='FC8'
An indication will be thrown whenever a switch has been removed from
the fabric.