Download Print this page

Qlogic 3000 Series Reference Manual page 60

Fibre channel switch
Hide thumbs Also See for 3000 Series:

Advertisement

3–Fabric Zoning Classes
QLGC_ZoningService : CIM_ZoneService
SystemName
Name
RequestedSessionState
OperationalStatus
SessionState
ActivateZoneSet
3-4
Property will contain the switch WWN.
Property will contain the switch WWN
Property will contain the enumerated value 5=NotApplicable.
Sessions are not supported.
Property will contain the enumerated value 2=OK
Property will contain the enumerated value 5=No Change. Applicable.
Sessions are not supported.
Method will attempt to activate the referenced zoneset, or to deactivate
the active zoneset. Observable (via CIM) effects of activating a
zoneset.
Any zone or zoneset object currently marked as active are
deleted.
Zone members that had been associated with the deleted
zones are deleted.
A copy of the referenced zoneset object is created and marked
as active.
Copies of all zones that participate in the reference zoneset are
created, marked as active and associated with new active
zoneset object.
Copies of all zone members that participate in the original
zones (including expanded zone aliases) are created and
associated with the the new zones.
Parameters:
Zoneset: [required] Reference to Zoneset to activate or
deactivate.
Activate: [required] If true, activate referenced zoneset,
otherwise deactivate zoneset.
59223-03 E

Advertisement

loading

This manual is also suitable for:

5000 series9000 series