Electrical; Environmental; A.5 Electrical; A.6 Environmental - Qlogic SANbox 5000 Series Installation Manual

Fibre channel
Hide thumbs Also See for SANbox 5000 Series:
Table of Contents

Advertisement

A
A.5

Electrical

Operating voltage ........................... 100 to 240 VAC; 50 to 60 Hz
Power source loading (maximum) .. 1 A at 120 VAC
Heat Output (maximum) ................. 100 watts
Circuit Protection ............................ Internally fused
A.6

Environmental

Temperature
Operating ..................................
Non-operating ...........................
Humidity
Operating ..................................
Non-operating ...........................
Altitude
Operating ..................................
Non-operating ...........................
Vibration
Operating ..................................
Non-operating ...........................
Shock
Operating ..................................
Non-operating ...........................
Air flow ............................................ Front-to-back
59096-04 A
0.5 A at 240 VAC
5 to 40°C (41 to 104°F)
-40 to 70°C (-40 to 158°F)
5% to 90%, non-condensing
5% to 93%, non-condensing
0 to 3048m (0 to 10,000 feet)
0 to 15,240m (0 to 50,000 feet)
IEC 68-2
5-500 Hz, random, 0.21 G rms, 10 minutes
5-500 Hz, random, 2.09 G rms, 10 minutes
IEC 68-2
4 g, 11ms, 20 repetitions
30g, 292 ips, 3 repetitions, 3 axis
A – Specifications
Electrical
A-5

Advertisement

Table of Contents
loading

Table of Contents