Configuring Port Threshold Alarms

The switch can monitor a set of port errors and generates alarms based on
user-defined sample windows and thresholds. These port errors include the
following:
Cyclic Redundancy Check (CRC) errors
Decode errors
ISL connection count
Device login errors
Device logout errors
Loss-of-signal errors
You make changes to the port threshold alarms by modifying the switch
configuration as described in
Refer to
The switch will down a port if an alarm condition is not cleared within three
consecutive sampling windows (by default 30 seconds). Reset the port to bring it
back online. An alarm is cleared when the threshold monitoring detects that the
error rate has fallen below the falling trigger.
59183-03 A
"Modifying a Switch Configuration" on page
Table 14-23
for a description of the port alarm threshold parameters.
6 – Port Configuration
Configuring Port Threshold Alarms
5-13.