2-8. Selecting Line Voltage

The calibrator arrives from the factory configured for the line voltage normally
appropriate for the country of purchase, or as specified at the time of your purchase order.
The calibrator also comes with the appropriate line power plug for the country of
purchase. If you need a different type, refer to Table 2-2 and Figure 2-2. They list and
illustrate the line power plug types available from Fluke.
Check the line power label on the rear panel of the calibrator to verify that the line
voltage matches local line power. Figure 2-3 shows the location of the line power label.
You can set the calibrator to operate from eight different nominal line voltages; each
voltage setting has a voltage tolerance of ± 10%, and frequency range of 47 to 63 Hz. The
line voltage switches are located on the bottom left side of the rear panel.
To change the line voltage setting, set the line voltage selection switches to the correct
setting shown in Figure 2-3.
Type
North America
North America
Universal Euro
United Kingdom
Switzerland
Australia
South Africa
LC-1
2-6
Table 2-2. Line Power Cord Types Available from Fluke
Voltage/Current
120V/15A
240V/15A
220V/16A
240V/13A
220V/10A
240V/10A
240V/5A
LC-2
LC-5
Figure 2-2. Line Power Cord Types Available from Fluke
Fluke Option Number
LC-1
LC-2
LC-3
LC-4
LC-5
LC-6
LC-7
LC-3
LC-6
LC-4
LC-7