Extreme Networks ExtremeWare Version 7.8 Troubleshooting Manual page 36

Advanced system diagnostics
Table of Contents

Advertisement

Packet Errors and Packet Error Detection
• Backplane link—Indicates that health check packets were lost on one or more backplane
links connecting an MSM module to an I/O module. Either module might be in error; check
the transceiver diagnostics.
• FDB error—Indicates that a discrepancy was detected during the FDB scan of the RAM
memory pool.
error
The error condition that summarizes the failure. One of many values that points to a specific
hardware component or software test (for further problem isolation).
The PBUS checksum type might indicate a problem with the packet memory, but it might also point to
other problem types, indicating failures with other hardware components detected during additional
checking performed under the umbrella of the Extreme diagnostics suite. For example, any other
component in the path between the ingress and egress points could malfunction, resulting in a
corrupted checksum. You should be aware that PBUS checksum messages and conditions can be caused
by a packet memory failure, but that there are other possibilities as well. The packet memory scan
should always be used in conjunction with the extended diagnostics to check the integrity of all the
components.
Possible error conditions for PBUS action messages:
• CARD_HWFAIL_PBUS_CHKSUM_INT_ERROR
• CARD_HWFAIL_PBUS_CHKSUM_EXT_ERROR
• CARD_HWFAIL_PBUS_CHKSUM_EDP_ERROR
• CARD_HWFAIL_PBUS_CHKSUM_CPU_PKT_ERROR
• CARD_HWFAIL_PBUS_CHKSUM_CPU_PKT_DIAG_ERROR
36
Advanced System Diagnostics and Troubleshooting Guide

Advertisement

Table of Contents
loading

Table of Contents