Getting Started with EPICenter
Note that in order to have any of these events cause an alarm in the EPICenter Alarm System, you need
to define an alarm that responds to a CPU Utilization Rising Threshold or CPU Utilization Falling
Threshold event.
• If you define an alarm based on the CPU Utilization Rising Threshold event, an EPICenter alarm will
occur at the initial sample, and at points A and C. Because the alarm was defined to respond to CPU
Utilization Rising Threshold events, the falling threshold trap events that occur at points X and Y do
not trigger an EPICenter alarm.
• If you also define an alarm based on a CPU Utilization Falling Threshold event, then EPICenter
alarms would be generated at points X and Y.

Using Topology Views

EPICenter topology views let you create visual representations of your network showing the devices,
links between devices, and basic status of those devices and links, including link utilization statistics
and VLAN membership and configuration information.
EPICenter automatically creates a default view with a set of network maps based on the IP addresses of
the management interfaces in the devices on your network. You can create multiple additional Topology
views to meet whatever needs you have. You can create Topology views that represent the physical
topology of your network (buildings, floors, wiring closets and so on), the logical topology of your
network (by operating divisions, departments, or workgroups) or by functional groupings (core devices
vs. edge devices, ESRP devices, EAPS rings, and so on).
A Topology View consists of a root map and submaps. Within a given Topology view, devices can be
represented only once, but the same devices can appear in multiple Topology Views—while the maps
and submaps within a view are interrelated, Topology Views are independent of each other. This allows
you to create multiple views of your network for different purposes.