Setting

Filter counter

This function is used to set a frequency for the filter replacement.
Use the Point ▲▼ buttons to select Filter counter and then press
the Point
or the SELECT button to access the submenu items.
Filter counter.............. Show the total accumulated time of the filter
Timer .......................... To set a timer, when the projector reaches
Filter counter reset.... When replacing the Filter cartridge, reset
Scrolls remaining . ..... When the filter scroll is counted down to 1,
Scroll counter Reset.. When replacing the Filter cartridge, reset
Note:
• Do not reset the counter when the filter or the filter cartridge is not
replaced.
• Timer setting notifies that the filter needs replacement. To replace the
filter, use the filter control function (p.56).
Test pattern
Various test pattern are available for use when setting up the
projector.

Factory default

This function returns all setting values except for User logo, PIN
code lock, Logo PIN code lock, Filter timer, Filter counter, built-
in network settings and network settings (including AMX D.D.) with
connecting optional Pj-to NetDirector to the factory default settings.
62
use timer setting.
the time, the Filter replacement icon (Fig.
1) appears on the screen and the total
accumulated time turns red, indicating
that the filter replacement is necessary. If
the filter is out of scroll and the projector
reaches a time set in the timer setting, Fig.
2 appears on the screen, indicating that the
filter cartridge replacement is necessary.
the Filter counter and the Scroll remaining
(p.65).
Scroll remaining on the screen is showing
0 scroll(s) , the last scroll icon (Fig. 3)
appears on the screen. When the filter scroll
is counted down to 0, the Filter cartridge
replacement icon (Fig. 4) appears on the
screen and the WARNING FILTER indicator
lights orange, indicating that the filter
cartridge replacement is necessary.
the Filter counter and the Scroll remaining
(p.65).
Filter counter
Filter counter
Timer
Filter counter reset
Scrolls remaining
Scroll counter Reset
Press the SELECT button to select Timer and then use
the Point ▲▼ buttons to set the timer. Select from (Off/
400H/700H/1000H) depending on the use environment.
Fig .1 Filter replacement icon
Filter replacement icon appears on the screen
at a set time.
Fig .2
Fig .3 Last scroll icon
Last scroll icon appears on the screen when
the filter is down to the last scroll.
Fig .4 Filter cartridge replacement icon
Filter cartridge replacement icon appears on
the screen when the filter scroll is counted
down to 0 scroll.  
Note:
• Fig.1, Fig. 2, Fig. 3 and Fig. 4 appear at turning on
and selecting input source.
• Fig.1, Fig. 2, Fig. 3 and Fig. 4 will not appear when
the Display function is set to Off (p.52) or during
Freeze (p.30).
150 H
32H
400 H
9 Scroll(s)