P6SD SERIES 13 SEER SINGLE PACKAGE CONVERTIBLE AiR CONDiTiONER Premium Model Shown Please read this information thoroughly and become familiar with the capabilities and use of your appliance before attempting to operate or maintain this unit. Keep this literature where you have easy access to it in the future. If a problem occurs, check the instructions and follow recommendations given.
Safety information ............WARRANTY INFORMATION About the Air Conditioner ......... A warranty certificate with full details is included with the Operating Instructions ..........Air Conditioner. Carefully reviewthese responsibilities with Cooling Operation ............. your dealer or service company. The manufacturer will not Heating Operation .............
SAFETY INFORMATION IMPORTANT: Please r ead allinstructions before servicing thisequipment. Payattention toallsafetywarnings a nd anyotherspecial n otes highlighted i nthemanual. Safety markings a reusedfrequently t hroughout thismanual to designate a degree orlevel o fseriousness andshould not beignored. WARNING indicates a potentially h azardous situation t hatifnotavoided, could result i npersonal injury or death.CAUTION indicates a potentially h azardous situation t hatifnotavoided, may result i nminor o rmoderate...
SAFETY INFORMATION /L WARNING: IMPORTANT: Safetymarkingsare usedfrequently throughout this manual t o designate a degreeor level Do not place combustible material on or against of seriousness a ndshouldnotbe ignored. W ARNING unit cabinet. Do not place combustible indicatesa potentiallyhazardoussituation that if materials, including gasoline...
GENERAL INFORMATION Locating the Air Conditioner Packaged AirConditioner unitsareready for easyand • Survey the job site to determine the best location for immediate i nstallation o nrooftops orground level s labs. mounting the outdoor unit. Unitsare shipped for horizontal ductconnections a nd •...
Ductlining must b eULclassified b atts orblankets w ith AIR CONDiTiONER INSTALLATION a firehazard classification ofFHC-25/50 o r less. Packaging Removal Fiberductworkmaybeusedinplaceofinternal duct Remove the shipping carton and User's Manual from linersif thefiberductworkis inaccordance w iththe the equipment. Take care not to damage the tubing current r evision o ftheSMACNA c onstruction standard connections when removing...
Figure 5. Internal Filter Rack Location Removal of internal Filter Rack (3 Phase Only) Figure 3. Ground Level Installation Remove the return air panel from the unit. Rooftop Remove the height adjustment screw from the inside Rooftop installations must be located according to local of the rack, building codes or ordinances and these requirements: Remove (1) screw securing the assembly to the...
samesizeandprimewithwater. W henconnecting r igid switch shall be capable of electrically de-energizing the drain line,hold thefemale fitting witha wrench toprevent outdoor unit. See unit data label for proper incoming field twisting. D onot overtighten! Refer t olocal c odesand wiring. Any other wiring methods must be acceptable restrictions forproper c ondensate disposal requirements.
C22.1Electrical Code.Usethe grounding lugprovided COPPER WIRE SIZE -- AWG inthecontrol b oxforgrounding t heunit. (1% Voltage Drop) Unbalanced Supply Wire Length-Feet Supply Circuit 3-Phase Supply Voltage Ampacity Voltage unbalance occurs when the voltages of all phases of a 3-phase power supply are no longer equal. This unbalance reduces motor efficiency and performance.
The blower speed is preset at the factory for operation at Fixed Torque ECM Motor the same speed for heating and cooling. These factory Shut off all electrical power to the unit and remove settings are listed in Table 5 (page 16).For optimum the blower panel.
START UP & SYSTEM CHECK .S.ystem Heating If the unit has been equipped with optional electric heater Pre-Start Check List kits, set the thermostat's system mode to HEAT and the Verify the unit is level and allows condensate to drain. fan mode to AUTO.
step 4, then there is too much charge in the system. Remove refrigerant and repeat steps 1 through 3 until the system is correctly charged. If the pressure measured in step 1 is less than the required liquid refrigerant pressure determined in step 4, then there is too little charge in the system.
Page 17
Convertable Packaged Air Conditioner 208/230Volt Three Phase 60Hz NOTES: 1. Disconnect an power before servicing. 1. Couper le courant avant de fake letretien. 5. For supply wire ampacities and overcurrent protection, see unit 2. For supply connections use copper conductors only. 2.
Page 18
Convertable Packaged Air Conditioner 208/230Volt Three Phase 60Hz NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3. Not suitable on systems that exceed 150 V to ground.
Convertible Packaged Air Conditioner 208/230 Volt Single Phase / 60Hz NOTES: 1. Disconnect all power before servicing. 4. If any of the original wire as supplied with the furnace must be replaced, it must 1. Couper le courant avant de faire letretien. 2.
Page 20
Convertible Packaged Air Conditioner 208/230 Volt Single Phase / 60Hz NOTES: 1. Disconnect all power before servicing. 4. If any of the original wire as supplied with the furnace must be replaced, it must 1. Couper le courant avant de faire letretien. 2.
WIRING DIAGRAM 460 Volt Three Phase 60Hz Convertable Packaged Air Conditioner NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 4. For supply wire ampacities and overcnrrent protection, see unit 2. For supply connections use copper conductors only.
Page 22
WiRiNG DIAGRAM 460 Volt Three Phase 60Hz NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3. If any of the original wire as supplied with the furnace must be replaced, it must be replaced with wiring material having a temprature rating of at least 105°C.
COOLING CHARGING CHARTS = 14 SEER A.C. P6SD-X36 Charging Chart - Cooling Liquid Temperature (oF) Figure 18. Charging Chart for 3 Ton Units P6SD-X48 Charging Chart - Cooling 56(3_ Rem°ve refrigerant when ab°ve curve b 520! 5oo! 460! 440- 420- ../"...
Page 24
Chart for 2 Ton Units INSTALLER PLEASE LEAVE THESE iNSTALLATiON iNSTRUCTiONS WiTH THE HOMEOWNER. NORDYNE O0 M F_L_E; COMFORT. GENUINE VALUE. Specifications & illustrations subject to change without notice or incurring obligations. O'Fallon, MO I Printed in U.S.A. (09/10) 709133A (Replaces 7091330)