Grounding the Cabinet

Attaching the Ground Wire

To attach the ground wire:
1.
Loosen the lug on the cabinet's ground connection.
Run a 12 AWG stranded copper wire from the ground lug to Electrical Service Ground.
2.
3.
Firmly retighten the lug loosened in step 1 above.
DSX-40 Hardware Manual
You must connect your system to Electrical Service Ground.
To Electrical
Service Ground
Figure 4: Attaching the Ground Wire
In case of fire, disconnect the power cord from the AC outlet.