Plug In Grill; Conversion To Lp Gas - KitchenAid KBSS361T Manual

Built-in insulated jacket outdoor grills
Table of Contents

Advertisement

Available languages

Available languages

3.
4.
1.
If local codes permit, use an outdoor flexible stainless
steel tubing gas connector, design-certified
by CSA
International,
to connect the grill to the rigid gas supply
line. A 5/8"diameter line is recommended.
Using a wrench
to tighten, connect the gas supply to the grill. Use pipe-
joint compound
on all non-flared male threads. Do not
kink or damage the flexible connector when moving the
grill.
Pipe-joint compounds
suitable for use with Natural gas
must be used. Do not use Teflon ®tape.
A
.................................
S
............................
D
...........
C
A. Grifl gas pipe
B. New CSA International
approved
"outdoor" flexible gas supply fine
C. Rear of grill
D. To Natural gas supply
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
Test all connections
by brushing on an approved
noncorrosive
leak-detection
solution. Bubbles will show a
leak. Correct any leak found.
This built-in outdoor grill comes with a 5,000 mAmp power
transformer plug assembly for the grill lights and igniter. Plug
in the single-prong
plug in the receptacle on the left
underside of the grill.
A. Single-prong plug
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
2. Plug into a grounded 3-prong outlet.
3. Gently slide grill completely
into outdoor enclosure.
4. Now go to the "Check and Adjust the Burners" section.
"......... 0 ...............................
IMPORTANT:
If LP gas conversionisdesired, f ollow
requirements outlined in the "Gas Connection
Requirements"
section.
Explosion Hazard
Use a new CSA international
approved
"outdoor"
gas supply
line.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 11" (28 cm) water
column.
Examples of a qualified
person include:
licensed heating
personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
IMPORTANT: A 20 Ib LP gas fuel tank must be purchased
separately.
IMPORTANT: The gas pressure regulator/hose
assembly
supplied with the conversion kit must be used. Replacement gas
pressure regulator/hose
assembly specific to your model, is
available from your outdoor grill dealer.
12