Burner Requirements for High Altitude
Input ratings shown on the model/serial
rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level. Orifice
conversion is required for elevations above 2,000 ft (609.6 m).
See "Assistance
or Service" section to order High Altitude
Conversion Kit.
Gas Supply Line Pressure Testing
Testing above 1/2psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge):
The grill and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures greater than 1/2psig (3.5 kPa).
Testing below 1/2psi (3.5 kPa) or 14" (35.5 cm) WOP (gauge) or
lower:
The grill must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to
or less than 1/2psig (3.5 kPa).
Natural Gas
Built-in grill models are equipped for use with Natural gas. They
are design-certified
by CSA International for LP (propane) gases
with appropriate
conversion.
Built-in models are set for Natural gas use and have a pressure
regulator with 1/2"female pipe threads.
A
, ,//
............................
D
"C
A. Grill gas pipe
B. New CSA International
approved
"outdoor" flexible gas supply line
C. Rear of grifl
D. To Natural gas supply