Operation - Fedders 23-23-0363N-002 Installation & Operation Manual

Room air conditioners for double hung windows
Table of Contents

Advertisement

• TIMER
....
S
• MED
• COOL •FAN
D
ON/OF_
........................ A
A.
Power
Control
B. Set Temperature/Timer
Display
C. Temperature/Timer
Hour
Control•
D. Mode
Control
E.
Fan Speed
Control
F. Timer
Control
Built-in
three minute
timing
delay.
This electronic controlled unit will not automatically
resume operation after a power failure.
If this electronic unit will not respond to touch pad or
remote control commands, it is necessary to unplug the
unit from the electrical outlet for five seconds and then
plug the unit back in.
pv_
Ea_:,lujn/[o_
_
Heat/Cool models or units with elec-
tric heat are designed to be used only
as a supplemental
heat source. They
should be used in addition to regular
heating systems and never as the pri-
mary source of heat.
OPERATION
")
Power
Control
The Power Control
turns
the unit
on and off.
Set
Temperature/Timer
Display
Shows the set temperature
when
the unit
is in operation
and hours
when
the timer
is being
set. THE TEMPERATURE
DISPLAY
ONLY
SHOWS
THE SET TEMPERATURE,
NOT
THE ACTUAL
ROOM
TEMPER-
ATURE.
Temperature/Timer
Hour
Controls
These
buttons
are used to raise or lower
the set temperature
in incre-
ments
of 1 o from 66°F to 88°F. By depressing
both
buttons
at once,
the
display
will
toggle
between
Celsius
and Fahrenheit.
When
the timer
is
being
set, these
buttons
are used to change
the hour setting
in incre-
ments
of I from 00 to 24.
Check
Filter
Light/Reset
(some models)
After
250 hours of usage the Check
Filter
light
will
turn on. At this time,
the filter
needs to be removed
and cleaned
(see page 8). After the filter
is cleaned
and repositioned,
depress
the
Reset
button.
This will
restart the counter
and turn the light off.
Mode
Control
A green light will indicate which mode is currently
being utilized.
Cool
Mode - The unit will circulate and cool the air.
Heat
Mode
(Heat
Models
Only)-
The unit will circulate and heat
the air.
Heater Safety Feature- When heater is powered off, low fan will auto-
matically stay on and run for 60 seconds to ensure the removal of resid-
ual heat, meanwhile,
the Low Fan LED blinks until the low fan stops.
Fan Mode
- The unit will only circulate the air.
Energy
Saver
Mode
-
(The energy
saver mode
is designed
to operate
with
Cool
mode
only)
The fan will
switch
from the set fan speed to LO whenever
the compres-
sor turns
off in response
to the thermostat.
When
the compressor
cycles
back
on, the unit will
return
to the original
fan setting.
Fan
Speed
Control
High,
Medium*,
Low
and
Auto
The settings
are adjusted
with
the Fan Speed Control,
each time
the [)Lit-
ton is depressed
it changes
the setting.
A green light
will
indicate
which
setting
is currently
being
used.
When
the AUTO
feature
is selected
while
the air conditioner
is in the
COOL
or HEAT mode,
the fan speeds will
change
automatically
as the
temperature
in the room
changes.
COOL
Mode
• 7 ° or more
above
the set temperature
will use HI FAN.
• 4 ° or less above
the set temperature
will use LO FAN.
HEAT Mode
(Heat models
only)
• 9 ° or more
below
the set temperature
will use HI FAN.
• 4 ° or less below
the set temperature
will use LO FAN.
*MEDIUM
FAN NOT
available
on HEAT models.