Download Print this page

Kenmore 11062182100 Owner's Manual page 9

Electric and gas commercial stacked dryer

Advertisement

2.Remove h old-down s crewandterminal b lock cover.
Terminal block cover
Hold-downscrew
3. Attach a _-inch, U.L.-listed, strain relief to the hole
below terminal block opening. Strain relief should have
a tight fit with dryer cabinet and be in a horizontal
position. Put the direct wire cable through the strain
relief.
Center silver-colored
Externalground
terminal block screw
coeeector
%%
w,re
///__"
0
(white)
/L-
....
Neutral grounding
wire (green/yellow)
_", U.L.-listed,
strain relief
Alternate
Connection:
If local codes do not permit the connection of a frame-
grounding conductor to the neutral wire:
1. Disconnect power.
2. Make sure the power supply cord or direct wire cable is
in place.
3. Remove the neutral grounding wire (green/yellow wire)
from external grounding connector screw. Loosen or re-
move terminal block screws. Connect neutral grounding
wire and the neutral wire (white or center) of power
supply cord or direct wire cable under the center screw
of the terminal block.
4. Connect the other two wires to outer terminal block
screws. Tighten all terminal block screws firmly.
5. Tighten the strain relief screws.
6. Insert tab of terminal block cover into slot of the dryer
rear panel. Secure cover with hold-down screw.
7. Connect separate copper grounding wire from external
ground connector to an adequate ground. If codes
permit and a separate grounding wire is used, it is
recommended that a qualified electrician determine that
the grounding path is adequate.
Neutral
grounding w ire
(green/yellow)
4. Loosen or remove terminal block screws. Connect the
neutral wire (white or center) of direct wire cable under
the center screw of the terminal block.
• Place the hook-shaped end of the wire over the
terminal block screw. The open side of the hook
should face to the right. Squeeze hook end of wire
together to form a loop.
5. Connect the other two wires to outer terminal block
screws using the same method(s) described in step 4.
Tighten all terminal block screws firmly.
6. Tighten the strain relief screws.
7. Insert tab of terminal block cover into slot of the dryer
rear panel. Secure cover with hold-down screw.
NOTE: If local codes do not permit the connection of a
frame-grounding conductor to the neutral wire, see the
instructions for "Alternate Connection," page 9.
External
ground
connector
determined by a
qualified electrician
m