Download Print this page

Kenmore 11062182100 Owner's Manual page 11

Electric and gas commercial stacked dryer

Advertisement

• Foreaseof installation, operation, andservicing
adequate space shouldbeprovided around thedryer.
• A 1/8-inch NPTplugged tapping, a ccessible f ortest
gaugeconnection, mustbe installed immediately
upstream of thegassupply connection t o thedryer.
Thedryermustbedisconnected fromthegassupply
piping system duringanypressure testing ofthe
system attestpressures i nexcess of 1!2psig.
Thedryermustbeisolated fromthegassupplypiping
system by closing the equipment shut-off v alveduring
anypressure t estingofthegassupply pipingsystem at
testpressures e qual t oor lessthan1/2psi(3,45kPa).
Test a llconnections b ybrushing on anapproved n on-
corrosive leak-detection solution. Bubbles w illshowa
leak. C orrect a nyleakfound.
Electrcal Shock Hazard
Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use art adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
1/8" pipe plug
(for checking
inlet
gas pressure
line (black iron
pipe)
Flexible r;
connecto
0
• Pipe joint compounds that resist the action of L.R gas
must be used. Do not use Teflon tape.
Important: Observe all governing codes and
ordinances.
A 120-volt, 60-Hz, AC-only, 15-or 20-ampere fused
electrical supply is required. A time-delay fuse or circuit
breaker is recommended.
It is recommended that a separate circuit serving only
this appliance be provided.
If codes permit and a separate ground wire is used,
it is recommended
that a qualified electrician
determine that the ground path is adequate.
Recommended
ground method
The dryer, when installed, must be electrically grounded
in accordance with local codes, or in the absence of
local codes, with the National Electrical Code,
ANSI/NFPA 70*.
GROUNDING
INSTRUCTIONS: This appliance must be
grounded. In the event of malfunction or breakdown,
grounding will reduce the risk of electric shock by
providing a path of least resistance for electric current.
The power supply cord plug must be plugged into an
appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
Copies of the standards listed above may be obtained from:
* National Fire Protection Association
One Batterymarch
Park
Quincey, Massachusetts
02269
11