Download Print this page

Kenmore 11062182100 Owner's Manual page 5

Electric and gas commercial stacked dryer

Advertisement

Four-Wire
Power Supply Cord Connection
Fire Hazard
Use a new UL approved 30 ampere power
supply cord.
Use a UL approved strain relief.
Disconnect power before making electrical
connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected
to green ground connector.
Connect remaining 2 supply wires to remaining 2
terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. The power supply cord
must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all
local codes and ordinances.
WARNING:
Improper connection of the
equipment-grounding
conductor can result in a risk of
electric shock. Check with a qualified electrician or
serviceman if your are in doubt as to whether the
appliance is properly grounded.
Do not modify the plug on the power supply cord. If it
will not fit the outlet, have a proper outlet installed by
a qualified electrician.
SAVE THESE INSTRUCTIONS
IMPORTANT:
A four-wire connection is required where
local codes do not permit the use of three-wire
connections.
Four-wire
Power Supply
Cord
For four-wire installations, the power supply cord must
have four, No.-10 copper wires and match a four-wire
receptacle of NEMA Type 14-30R.
The fourth wire (grounding conductor) must be identified
with a green cover or bare copper wire and the neutral
conductor by a white cover.
1. Disconnect power.
2. Remove hold-down screw and terminal block cover.
3. Attach a ¾-inch U.h-listed, strain relief to the hole
below terminal block opening. Strain relief should have
a tight fit with dryer cabinet and be in a horizontal
position. Put the power supply cord through the strain
relief.
Terminal block cover
Hold-down screw
@=_n
%
4. Remove the center terminal block screw. Remove the
neutral grounding wire (green/yellow wire) from
external grounding screw.
Externalground
Center silver-colored
connector_
terminal block screw
/
Green/yeg0w wire
ofharness
5. Connect neutral grounding wire from machine and the
neutral wire (white) of power supply cord under the
center screw of terminal block.
6. Connect the other two insulated wires to outer terminal
block screws.
7. Connect the green or bare, grounding wire from the
power supply cord to the external grounding conductor
screw. Tighten all terminal block screws firmly.
8. Tighten the strain relief screws.
9. Insert tab of terminal block cover into slot of the dryer
rear panel. Secure cover with hold-down screw.
Center silver-colored
External ground
terminal block screw
connector
of power supply
cord or bare
copperwire
5