5.Connect neutral g rounding w ireandtheneutral w ire
(white orcenter) o fdirect w irecableunder thecenter
screwofterminal b lock.
Center silver-colored
terminal block screw
Externalground
groundingwire
(green/yellow)
Bare copperwire
Y/', U.L.-listed,
strain relief
6. Place the hook-shaped end of the wire over the
terminal block screw. The open side of the hook
should face to the right. Squeeze hook end of wire
together to form a loop.
7. Connect the other two wires to outer terminal block
screws. Use the same method described in Step 6.
8. Connect the direct wire cable (bare) grounding wire to
the external-grounding
conductor screw. Tighten all
terminal block screws firmly.
9. Tighten the strain relief screws.
10. Insert tab of terminal block cover into slot of the dryer
rear panel. Secure cover with hold-down screw.
Grounding
Instructions
• For a grounded, cord-connected
dryer:
This dryer must be grounded.
In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock or breakdown; grounding will
reduce the risk of electric shock by providing a path
of least resistance for electric current. This dryer
uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
• For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent-wiring
system, or an equipment-
grounding conductor must be run with the circuit
conductors and connected to the equipment-
grounding terminal or lead on the dryer.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service
representative or personnel if you are in doubt as to
whether the dryer is properly grounded.
Do not
modify the plug on the power supply cord: if it will not
fit the outlet, have a proper outlet installed by a
qualified electrician.
SAVE THESE INSTRUCTIONS
Three-Wire
Power Supply Cord Connection
Fire Hazard
Use a new UL approved 30 ampere power
supply cord.
Use a UL approved strain relief.
Disconnect power before making electrical
connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected
to green ground connector.
Connect remaining 2 supply wires to remaining 2
terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.