Converting To Lp Gas - Kenmore 362.7262 Use & Care Manual

Hide thumbs Also See for 362.7262:
Table of Contents

Advertisement

Available languages

Available languages

STEP 9
Installing
the Anti-Tip
Device
WARNING:
= Range must be secured with an approved Anti-Tip
device.
,, Uniess properly installed, the range could be tipped
by you or a child standing, sitting or leaning on an
open door°
o After installing the Anti-Tip device, verify that it is
properly installed and engaged by removing the
storage drawer and inspecting the rear leveling leg..
Make sure it fits securely into the slot
. This range has been designed to meet al!
recognized industry tip standards for all normal
conditions.
° The installation of the Anti-Tip device must meet all
local codes for securing the app]iance..
• The use of this device does not preclude tipping of
the range when not properly installed.
• If the Anti-Tip device supplied with the range does
not fit this application,
use the universal Anti-Tip
device WB2X7909.
Call 1-800-4-MY-HOME _'.
These Anti-Tip device installation instructions are for
wood or concrete floors and walis. Any other type of
construction
may require special installation techniques
to provide adequate fastening of the anti-tip device to
the floor and wall..
1. Locate the device against the rear wail and either the
fight or left cabinet, if the countertop overhangs the
cabinet, offset the device from the cabinet by the
amount of overhang.. If there is no adjacent cabinet,
position the edge of the device at the desired location
of the range side panel.
2. Use the device as a
Adacenl Cabtnet o r
template and mark 2
F na!Localonor
Range
hole positions on the
Stde
Panel \
:
WeltHoles
wall and 2 hole
weea"'-F:a r_'_
`'j/,n r I _'._f
!
positions on the floor:
Holes k = Iq-"_'_,,_J
Use either the wood
.......
or concrete floor
Aeri'Tl' ' =LqJ_k"J-,_
j
.-JJ)J _ t
set of positions,
_//__
Concrete
depending on your
'_
_
Fleer
floor type.
Holes
RearLeveling
Legof Range
3. For wood construction, drill a 1/e"pilot hole in the
center of each of the pre-marked wood floor and
wall hole positions (a nail or awl may be used if a drill
is not available)° Fasten the Anti-Tip device with the
4 screws provided..
AtlashmenHowall
l:l
/
Anti-Tip Device
NIJ
Well plate
Screw must enter
fll I
l
L-t,
,oo, o, oo,0,
J__J
.,_\\\\\\\\\_\\\\\\\\\\\\\\\\\_1_
LJ
".-.j.
.
For concrete construction, you will need four'
_,,_" x 11/2"lag boits and four V2" OD. sleeve anchors
(not provided). Drill the recomrnended size hole for' the
anchors into the concrete at the center of each pre-
marked floor and wall hole position. Install the sleeve
anchors into the drilled holes and then install the lag
bolts through the device, Do not overtighten
the
bolts.
Slide the range against the wall, and check for proper
installation by removing the storage drawer and
inspecting the rear leveling leg_ Make sure it fits
securely into the slot on the Anti-Tip device.
WHEN ALL HOOKUPS ARE COMPLETED:
MAKE SURE ALL OF THE CONTROLS ARE LEFT
IN THE OFF POSITION°
MAKE SURE THE FLOW OF COMBUSTION
AND
VENTILATION AIR TO THE RANGE IS
UNOBSTRUCTED.
Converting to LP gas
(or converting back to natural gas from LP)
This range leaves the factory set for use with natural gas_
If you want to convert to LP gas, the conversion must be
performed by a qualified LP gas installer.
The conversion instructions, sticker and LP orifices
can be found attached to the range next to the
pressure regulator.
Keep these instructions and the orifices in case you want
to convert back to natural gas, Conversion back to
natural gas must be performed by a qualified installer:
46