Download Print this page
Kenmore 30 " ELECTRIC RANGE Installation Instructions
Kenmore 30 " ELECTRIC RANGE Installation Instructions

Kenmore 30 " ELECTRIC RANGE Installation Instructions

30" electric range
Hide thumbs Also See for 30 " ELECTRIC RANGE:

Advertisement

iNSTALLATiON
AND SERVICE
MUST BE PERFORMED
BYA QUALiFiED
iNSTALLER.
iMPORTANT:
SAVE FOR LOCAL ELECTRICAL
iNSPECTOR'S
USE.
READ AND SAVE THESE iNSTRUCTiONS
FOR FUTURE REFERENCE.
Clearances
and Dimensions
1.
Provide adequate clearances
between the range and adjacent combustibJe
surfaces.
2.
Location--Check
location where the range will be installed. Check for proper eiectricaJ supply, and the stability
of the
floor.
3,
Dimensions
that are shown must be used, Given dimensions
provide minimum clearance, Contact surface must be solid
and level.
RANGE
OVERALL
DIMENSIONS
25- 3/4"
...... _
3o'--.j___
/
_-_-
;6 + 1/8'
"
"
\
29-7/8"
.. _
uoor upen
\ 4r"'/_
_-- - -"
Fig.
1
Depthis 28-13/3Z' with door handle.
RANGEELECTRICAL
CONNECTIONS
__!1i
dimensionsfoi
"_
ectricaloutlet location I
re maximum.
J
h_/_
_j
Dashed cubedarea
/
_-Centenine showswhere the
|
!
ofrange
electrical outlet must
II
I
be installedfor flush to|
II
-_i 11h_ the wall installation.
2-5/8"for models equipped
withwarmer drawers,
3-1/2"for models equipped
withstorage drawers
Fig. 2
Minimumto
1"
wall on either
side of range
above 36" height.
SIDE
VIEW
t
Minimumto
1_-13"-_
18"
cabinetson
Maximumdepth
eitherside
for cabinets
II
,_
of range,
above rangetop.
Fig. 3
_25"_
iiill
i
i_
O"clearancebelow cookingtop and at rear of range.
*30" MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACEAND
THE BOTTOM OF AN UNPROTECTED WOOD OR METAL
CABI NET; OR 24" MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT LESS THAN 1/4" FLAME RETARDANT
MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEETSTEEL, 0.015" STAINLESS STEEL, 0.024"ALUMIN UM OR 0.020" COPPER.
0" CLEARANCE
IS THE MINIMUM FOR THE REAR OF THE RANGE. FOLLOW ALL DIMENSION
REQUIREMENTS
PROVIDED ABOVE TO
PREVENT PROPERTY DAMAGE, POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOPAND
CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE SPACE LOCATED
ABOVE THE SURFACE UNITS SHOULD BE AVOIDED.
IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN BE REDUCED BY
INSTALLING
A RANGE HOOD THAT PROJECTS
HORIZONTALLY
A MINIMUM OF 5" BEYOND THE BOTTOM OF THE CABINETS.
IMPORTANT
SAFETY
INSTRUCTIONS
@
e ALL RANGES
CAN TiP
• INJURYTO
PERSONS
COULD RESULT
e INSTALL ANTI=TIP
DEVICE PACKED WITH
RANGE
• SEE INSTALLATION
INSTRUCTIONS
If the information in this manual is not followed
exactly, a fire or electrical shock may result causing property
damage, personal injury or death,
Important Notes to the Installer
Read all instructions contained inthese installationinstructions
before installing range.
Remove all packing material from the oven compartments
before connecting the gas & electrical supply to the range.
Observe all governing codes and ordinances.
Be sure to leave these instructions with the consumer.
Important
Note to the Consumer
Keep these instructions with your owner's guide for future
reference.
As when using any appliance generating heat, there are
certain safety precautions you should follow. These are
listed in the Use & Care Manual read it carefully.
Be sure your range is installed and grounded properly by
a qualified installer or service technician.
Make sure the wall coverings around the range can
withstand the heat generated by the range.
To eliminate the need to reach over the surface elements,
cabinet storage space above the elements should be
avoided.
Serial Plate Locations:
Serial
pJate
location:
i_#_/_
_</
r
Serial plate is located on the lower right front frame of the appliance.
Alternate location may be under cooktop.
pin 316454905 (0703) EN
1
EspaSol- Paginas 5-8

Advertisement

loading

Summary of Contents for Kenmore 30 " ELECTRIC RANGE

  • Page 1 iNSTALLATiON AND SERVICE MUST BE PERFORMED BYA QUALiFiED iNSTALLER. iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE. READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE. Clearances and Dimensions Provide adequate clearances between the range and adjacent combustibJe surfaces. Location--Check location where the range will be installed. Check for proper eiectricaJ supply, and the stability of the floor.
  • Page 2 BEFORE STARTING 32" pilot hole 1-3/4" deep. The screws provided may be used in wood or concrete material. Use a 5/16" nut-driver or flat head Tools You Will Need screwdriver to secure the bracket in place (See Fig. 6). For leveling legs and Anti=Tip Bracket: , Adjustable wrench or channel lock pliers...
  • Page 3 MODELS REQUIRING POWER SUPPLY CORD KIT. RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IFAN INCORRECT SIZE RANGE CORD KIT IS USED, THE INSTALLATION INSTRUCTIONSARE NOT FOLLOWED OR STRAIN RELIEF BRACKET IS DISCARDED. This appliance may be connected by means of a power supply cord.
  • Page 4 or 4B, POWER CORD CONNECTIONS 3=Wire Connection (3=Wire Connection instructions. For existing installations ONLY Factory installed connections (DO NOT LOOSEN) = Refer to Fig. 13). Follow the manufacturer's installation instructions supplied with the Terminal strain relief and install (Also see Figs. 9, 10 & 11). connect Insert the end connectors for Line 1, Line 2 and Neutral and tighten Line 1...