PERFORMANCE DATA SHEET
Base Grille Water Filtration System
Model TIKB1/TIRFKB1
Capacity
100 Gallons
(379 Liters)
(_
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of
Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSl
Standard
53 for the reduction
of
Lead, Mercury, Atrazine,
Benzene,
Toxaphene,
O-Dichlorobenzene,
Cysts, Turbidity,
Asbestos,
Lindane,
Tetrachloroethylene,
Endrin, Alachlor,
Chlorobenzene,
Ethylbenzene,
TI-HM,
MTBE and VOC.
This system
has been
tested
according
to NSF/ANSl
Standards
42 and 53 for the reduction
of the substances
listed
below.
The
concentration
of the indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the
permissible
limit for water
leaving
the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.0 mg/L
2.0 mg/L _+10%
0.08 mg/L
**
2.0 mg/L
95.93
97.36
Particulate Class I*
85% reduction
3533333#/mL
At east 10,000 part c es/mL 22000 #/mL
11567 #/mL
99.38
99.67
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
150 ug/L
0.15 mg/L _+10%
1.0 ug/L
1 ug/L
99.33
99.33
Lead: @ pH 8.5
0.010 mg/L
157 ug/L
0.15 mg/L _+10%
2.0 ug/L
1.08 ug/L
98.72
99.31
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.53
96.53
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.5
96.5
Benzene
0.005 mg/L
15 ug/L
0.015 mg/L _+10%
0.5 ug/L
0.5 ug/L
96.67
96.67
O-Dichlorobenzene
0.6 mg/L
1750 ug/L
1.8 _+10%
1.0 ug/L
1.0 ug/L
99.94
99.94
Toxaphene
0.003 mg/L
15 ug/L
0.015 _+10%
1.0 ug/L
1.0 ug/L
93.33
93.33
Atrazine
0.003 mgiL
10 ug/L
0.009 mg/L _+10%
2 ug/L
2 ug/L
80.8
80.8
Asbestos
99%
101 MFL
107to 10Bfibers/L _t
0.17 MFL
0.17 MFL
99.83
99.83
Live Cysts _
>99.95%
120,000/L
50,000/L min.
8/12
1/L _
99.99
>99.99
Turbidity
0.5 NTU
11.4 NTU
11 _+1 NTU
0.41 NTU
0.24 NTU
96.4
97.89
Alachlor
0.002 mg/L
41.3 ug/L
0.04 _+10%
0.2 ug/L
0.2 ug/L
99.52
99.52
Endrin
0.002 mgiL
5.9 ug/L
0.006 _+10%
0.5 ug/L
0.3 ug/L
91.5
95.47
Ethylbenzene
0.7 mg/L
1867 ug/L
2.1 _+10%
0.70 ug/L
0.0588 ug/L
99.96
100
Lindane
0.002 mg/L
1.9 ug/L
0.002 _+10%
0.02 ug/L
0.02 ug/L
98.93
98.93
Chlorobenzene
0.6 mg/L
2.0 ug/L
2.0 _+10%
0.0005 ug/L
0.0005 ug/L
99.98
99.98
Tetrachloroethylene
0.005 mg/L
14.2 ug/L
0.015 _+10%
0.5 ug/L
0.5 ug/L
96.47
96.47
TTHM
0.080 mg/L
465 ug/L
0.45 _+20%
1.0 ug/L
0.5 ug/L
99.78
99.88
MTBE
0.005 mgiL
14 ug/L
0.015 _+20%
0.70 ug/L
0.52 ug/L
94.94
96.27
VOC
0.015 mg/L
0.3520 mg/L
0.300 _+10%
0.0060 mg/L
0.0008 mg/L
98.4
99.78
Test Parameters:
pH = 7.5 + 0.5 unless otherwise
noted.
Temp. = 68°F to 71.6°F (20°C to 22°C).
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
•
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
•
Model
T1KB1 : The filter monitor
system measures the amount of
water that passes through the filter and alerts you to replace the
filter.
Style
1 - When the filter indicator
reads 10%, order a new filter.
When the filter indicator
reads 0%, it is recommended
that you
replace the filter.
Style 2 - When the filter indicator
light changes
from green to
yellow, order a new filter. When the filter indicator
light changes
from yellow
to red, it is recommended
that you replace the filter.
Use replacement
cartridge
T1RFKB1,
part #9030. In Canada,
use
replacement
cartridge
T1RFKB1,
part #9030B.
2008 suggested
retail price of $41.99
U.S.A./S51.99
Canada.
Prices are subject to
change without
notice.
•
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
•
The product
is for cold water use only.
•
Do not use with water that is microbiologically
unsafe or of
unknown
quality without
adequate
disinfection
before or after the
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL
of AC Fine Test Dust.
ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters that may contain
filterable
cysts.
•
Refer to the front cover or "Accessories"
section
for the
Manufacturer's
name, address
and telephone
number.
•
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.9 L/min) @ 60 psi
24