Craftsman 919.167783 Owner's Manual page 17

Permanently lubricated 2-stage twin v portable air compressor
Hide thumbs Also See for 919.167783:

Advertisement

Available languages

Available languages

6.
After the water has been drained,
close the drain valve (clockwise).
The air compressor
can now be
stored.
NOTE: If drain valve is plugged,
release all air pressure.
The valve
can then be removed, cleaned, the
reinstalled.
Air Filter Inspection
and
Replacement
and cylinder
smeeve are very hot,
Do not touch, AHow compressor
to
cool prior to servicing.
A dirty air filter will not allow the
compressor to operate at full
capacity.
Keep the air filter clean at
a!l times.
1.
Remove the air filter cover.
2.
Remove the air filter and make
sure it is clean.
IMPORTANT:
Do not operate
the compressor with the air filter
removed.
3.
If dirty, rinse air filter with warm
water and squeeze dry.
4.
Replace air filter and air filter
cover
NOTE: If the air filter is extremely
dirty it will need to be replaced. Refer
to the "Repair Parts" for the correct
part number.
Air Compressor
Pump
Intake
and
Exhaust
Valves
Once a year have a Trained Service
Technician check the air compressor
pump intake and exhaust valves.
Motor
The motor has an automatic reset
thermal overload protector. If the
motor overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed
to cool down before restarting.
The
compressor
wi!l automatically
restart
after the motor cools.
if the overload protector
shuts the
motor off frequently, check for a
possible voltage problem.
Low
voltage can also be suspected
when:
1.
The motor does not get up to fuji
power or speed.
2.
Fuses blow out when starting
the motoK lights dim and remain
dim when motor is started and is
running.
17-ENG
A09710