Download Print this page
Craftsman 919.167783 Owner's Manual
Craftsman 919.167783 Owner's Manual

Craftsman 919.167783 Owner's Manual

Permanently lubricated 2-stage twin v portable air compressor
Hide thumbs Also See for 919.167783:

Advertisement

Available languages

Available languages

Quick Links

Owner's
Manuam
PermanentJy
Lubricated
2-Stage
Twin V
AIR COMPRESSOR
o
o
o
o
o
o
o
Safety
Guidelines
Assembly
Operation
Maintenance
Service
and Adjustments
Repair
Parts
CAUTmON,
Read the Safety Guidelines
and All hstructions
Carefully Before
Operating.
Sears,
Roebuck
and Co., Hoffman
Estates,
mL(}0179 U.S.A.
Visit our Craftsman
website:
www, sears,com/craftsman
A09710
R_v,o1/s/o._

Advertisement

loading

Summary of Contents for Craftsman 919.167783

  • Page 1 Twin V AIR COMPRESSOR Safety Guidelines Assembly Operation Maintenance Service and Adjustments Repair Parts CAUTmON, Read the Safety Guidelines and All hstructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, mL(}0179 U.S.A. Visit our Craftsman website: www, sears,com/craftsman A09710 R_v,o1/s/o._...
  • Page 2 FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in materiaJ or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge. Contact your nearest Sears Service Center (1-800-4-MY-HOME ®) to arrange for repair, or return the Air...
  • Page 3: Glossary

    Model No, 919-167783 Running HP Bore 2.375" Stroke High Pressure .54" Low Pressure 1.45" Voltage-Single Phase Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity - Gallons 25 ASME Approximate Cut-in Pressure Approximate Cut-out Pressure Refer to Glossary for abbreviations. This manual contains information...
  • Page 4 Save these instructions improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. WARNING: Risk of explosion or fire How To Prevent mt What Could Happen mtis normaB for eBectricam contacts...
  • Page 5: Accessories

    WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. Now To Prevent What Could NaoDen Drain tank daily or after each use. Failure to properRy drain condensed water from tank, causing rust and...
  • Page 6 WARNING: Risk of Electrical Shock Now To Prevent mt What Ceumd Happen Your air compressor is powered Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used Never operate compressor with...
  • Page 7 WARNING: Risk of Burns How To Prevent It What Could Happen Never touch any exposed met.a[ parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
  • Page 8 WARNmNG: Risk of Serious mnjury or Property Damage When Transporting Compressor (Fire, InhMatien, Damage to Vehicle Surfaces) Row To Prevent What Could Happen Oil can leak or spill and could result Always place COMPRESSOR on a in fire or breathing hazard; serious protective mat when transporting injury or death can result,...
  • Page 9 Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure CFM: Cubic feet per minute. at which the motor automatically SOFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Assembly

    Contents of Carton Assemble Wheels 1 - Air Compressor It win be necessary to brace or support Wheels one side of the air compressor 2 - Shoulder Bolts, 3/8-16 when installing the wheeBs because the compressor will have a 2 - Nex Nuts, 3/8-16 tendency to tip, 2 - Rubber Bumpers...
  • Page 11: Installation

    TO SET UP YOUR IMPORTANT: The outlet being used must be installed and grounded in UNiT accordance with all local codes and ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a has the same configuration clean, dry and well ventilated area.
  • Page 12: Operation

    Extension Cords Voltage and Circuit Protection Refer to the Parts Manual for the Using extension cords is not recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Risk of Unsafe and overheating.
  • Page 13 Know Your Air Compressor READ THiS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to famiIiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Safety Valve Description of Operation Tank Pressure...
  • Page 14 How to Use Your Unit Cooming System (not shown}: This compressor contains an advanced How to Stop: design cooling system. At the heart of 1= Set the On/Auto/Off lever to this cooting system is an engineered fan. It is perfectly normal for this fan "Off"= to blow air through the vent holes Before...
  • Page 15 After 15 minutes, close the drain to Start: valve (clockwise). The air receiver Turn the On/Auto/Off lever wilI fill to "cut-out" pressure and to "On/Auto" and allow tank the motor will stop. pressure to build. Motor will The compressor is now ready for use. stop when tank pressure reaches "cut-out"...
  • Page 16: Maintenance

    Customer Responsibilities Before Daily or after Every Every each each Yearly hours qours Check Safety Valve Drain Tank Air Filter Air compressor pump intake and exhaust valves 1- more frequent in dusty or humid conditions To Check Safety Valve cycles automatically when power is on, When servicing, you may...
  • Page 17 After the water has been drained, IMPORTANT: Do not operate close the drain valve (clockwise). the compressor with the air filter removed. The air compressor can now be stored. If dirty, rinse air filter with warm NOTE: If drain valve is plugged, water and squeeze dry.
  • Page 18 ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY A TRAINED SERVICE TECHNICIAN. cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or Unscrew the check valve (turn disconnect emectdcamsupply to...
  • Page 19 Assemble the regulator and To Replace Regulator orient as shown. Release alI air pressure from air tank, See "To Drain Tank" in the "Maintenance" section= Set the On/Auto/Off lever to "Off" and unplug unit. Remove the outlet pressure gauge and quick connect (if equipped) from the regulator.
  • Page 20 Before you store the air compressor, _Risk of Bursting, Water will make sure you do the following: condense in the air tank, if not Review the "Maintenance" drained, water will corrode section on the preceding weaken the air tank causing a risk pages and perform scheduled of air tank rupture.
  • Page 21: Service And Adjustments

    _Risk of Unsafe Operation, Unit cycles automatically when power ison, When servicing, you may be exposed voffage sources, compressed air, or moving parts, Before servMng unit unp{ug or disconnect emectdcamsupply to the air compressor, Meed tank of pressure, and allow the air compressor to cool PROBLEM CAUSE...
  • Page 22 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" if there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the...
  • Page 23 OAUSE OORREOTION PROBLEM Regulator will Damaged regulator. Replace. notshut offair outlet. Motor will not Let motor coot off and Motor overload protection run. overload switch will switch has tripped. automaticatly reset. Tank pressure exceeds Motor will start automatica!ly when tank pressure drops pressure switch "cut-in"...
  • Page 24 Air Compressor Model Number 919,167783 Torqueto A09710 24- ENG...
  • Page 25 Grip 7/8 DIA AC-0781 O-Ring .3621D x .103 width (2) AC-0802 interconnecting Tube SSF-8080-ZN Hex Nut 3/8 - 16 UNC - 2B LA-3105 Label, Craftsman LA-3027 Label, Drain Tank Z-D27352 Pump Assembly LA-3021 Label, Warning - not shown LA-3108 Label, Not Surface...
  • Page 26 Air Compressor Model Number 919o167783 Torque 19 7-10 ff.qbs. 7-10 ff,-Ibs, Torque 51-63 11 in.-Ibs. Torque 25-35 2 ft.qbs. 7 Torque 75-90 in.qbs. A09710 26-ENG...
  • Page 27 Air Compressor Model Number 919,167783 PART NO, DESCRIPTION Z-D26717 Motor D24596 Screw 5/16-24 x 1-3/4 (2) Assembly, Connecting Rod (High Pressure) D24597 Outer Eccentric ACG-22 39124607 Screw, Self Tapping 1/4 x 5/8 @ #+8 Cylinder Sleeve Assembly, Connecting Rod (Low Pressure) Compression Ring, Formed ..
  • Page 28 TOTAL DE UN ANO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materia!es o de fabricaci6n dentro del a_o de su fecha de compra, Sears, a su opci6n, Io reparar#_ o reemptazara sin costo alguno.
  • Page 29 ModeRo N" 919.167783 1,6 HP Potencia de trabajo ©rificio 2,375 pulg. (60,3 ram) CarFel'a Presi6n de alto -,54 pulg. (13,7 mm) Presi6n de mugir - 1,45 pulg. (36,8 mm) Voltaje-corriente manofAsica Requerimientos Minimos de Circuito 15 Amperios Retardo Tipo de Fusible Capacidad del Tanque de Aire - Galon 25 ASME (94,6L)
  • Page 30 GUARDE ESTAS |NSTRUCCiONES operaci6n o el mantenimiento inadecuados este producto podrian ocasionar sedas lesiones y dafios a la propiedad, Lea y comprenda todas advertencias e instrucciones de funcionamiento antes de utilizer este equipo, ADVERTENCIA: Riesgo de Explosi6n o mncendio puede occurrir c6mo preveniHo...
  • Page 31 ADVERTENCIA: Riesgo de E×plosi6n Tanque de aire: las siguientes condiciones podrfan, causar el debilitamiento del tanque, determinar su explosi6n violenta, danos a la propiedad o serias lesiones= qu_ puede occurrir c6mo prevenirRo Drenaje inadecuado del agua condeneada Drene el tanque diariarnente o despu_s en eUtaaque,...
  • Page 32: Conexi6N A Tierra

    ADVERTENCIA: Riesgo Descarga El_ctrica _-_i puede occurrir c6mo prevenir[o Su compresor de aire est& accionado Jam&s opere el compresor a [a intemperie electficidad. Come cua[quier otto dispositivo cuando est_ Iloviendo o en condiciones e_6ctrico irnpu[sado electdcamente, si no se le humedad.Nunca epere el compresor sin sus...
  • Page 33 ADVERTENCIA: Riesgo de Quernaduras qu_ puede occurrir c6mo preveniHo Jam_s toque partee de metal e×pueetas en eU Tocar el metal expuesto tal come el cabezal compresor durante o inmediatamente despues de! compresor o los tubes de salida de! escape, de la ope_aci6n, eUcompreeor permanecer_ puede ocaeionarie...
  • Page 34 iiiii, ADVERTENCIA: Riesgo de Sepias Lesiones o DaSos a la Propiedad Transportar el ¢ornpresor (Fuego, hhaUaci6n, daSo a la superficie de vehicuUos) puede occurrir c6mo preveniHo EU aceite puede derramarse y ello podria Deposite e_ eomp_eso_ sobre usa aUfombriHa resultar en serias _esiones o la muerte debido al protectora cuando Uotranspo_te,...
  • Page 35 Presi6n minima de eorte: Cuando el Familiadcese con los siguientes t6rminos, motor esta apagado, la presi6n del tanque antes de operar la unidad: de aire baja a medida que usted contin0a CFM: (Cubic feet per minute) Pies cObicos usando su accesorio. Cuando la presi6n pot minuto.
  • Page 36 Ensamble de las ruedas Contenido de macaja 1= Compresor de aire 2= Ruedas 2= Pernos con resalto, 3/8-16 pulg. del equipo cuando se instalan ruedas porque el compresor tender_ 2= Tuercas hexagonales, 3/8-16 pulg. voltearse. 2= Parachoques de goma Fije las ruedas con pernos con 2= Tornillos, 1/4=20 x 3/4 pulg.
  • Page 37 COMO PREPARAR LA UNIDAD AsegOrese de que el tomacorriente que serA utilizado tenga la misma configuraci6n que el enchufe de Ubicaci6n del compresor de aire conexi6n a tierra. NO UTILIOE UN Ubique al compresor de aire en una zona ADAPTADOR. Ver figura.
  • Page 38 CabBes de extensi6n el_ctrJca Protecci6n del voltaje y del circuito No se recomienda la utilizaci6n de cables Acerca del voltaje y la minima cantidad de de e×tensi6n el6ctrica. El uso de cables circuitos requeridos, refi6rase al cuadro de especificaciones. de extensi6n el6ctrica originara una caida de tensi6n, Io que determinar_ p6rdida de potencia del motor asf como compresores...
  • Page 39 Conozca su com_resor Qir@ LEA ESTE MANUAL DEL PROPIETARiO Y SUS NORMAS DE SEGURiDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 40 Sistema de enfriamiento mostrado}: Este compresor contiene C6mo utilizar su unidad un sistema de avanzada para el control de enfriamiento. En el nL_cleo C6mo detenerla: de este sistema de enfriamiento Coloque la posici6n de la Ilave un ventilador especialmente diseFiado. interruptora On/Auto/Off en la Resulta perfectamente...
  • Page 41 C6mo poner en marcha: Antes de cada puesta en marcha: Mueva la palanca On/Auto/Off a la Coloque el interrupter On/Auto/Off en posiciSn "On/Auto" y deje que se la posici6n "Off" y cierre el regulador de incremente la presi6n del tanque. El aire.
  • Page 42 Responsabilidades dem cliente Antes Diariamente Carla Carla AnuaJmente o luego de carla cads use Betas horas Verifique la v_lvula de seguridad • Drenaje del tanque Filtro de aire V_lvulas de entrada y escape de la bomba del compresor de aire 1- Mas frecuente en condiciones polvorientas o hOmedas.
  • Page 43 Siesta sucio enjuague el filtro de aire Riesgo de E×plosi6n. Dentro de[ tanque con agua tibia y exprimalo hasta que se producir& condensaci6n de agua. seque. Si no drena, el agua Io corroer_ Vuelva a colocar el filtro de aire y su cubierta.
  • Page 44 TODO T[PO DE MANTENIMIENTO Y OPERACIONES DE REPARAC[6N NO MENCIONADOS, DEBERAN SER EFECTUADOS POR PERSONAL TECNICO ESPE¢IALIZADO. Riesgo de Operaci6n [nsegura: La unidad arranea autom_ticamente cuando est& enehufada. AI hacer e[ mantenirniento, e[ operador puede quedar expuesto Desenrosque la vAIvula de retenci0n a fuentes de corriente y de aire...
  • Page 45 Ensamble el regulador y ori6ntelo de Para reemplazar emregumador acuerdo a Io mostrado. Libere toda la presi6n del aire del tanque. Vea "Drenaje del tanque" en la secci6n "Mantenimiento". Apagar la unidad colocando interrupter en On/Auto/Off en "Off". Usando una Ilave de tuercas ajustable retire el medidor de salida de presi6n y la conexi6n r_pida del regulador...
  • Page 46 Antes de guardar su compresor de aire, Riesgo de Explosi6n. asegOrese de hacer Io siguiente: El agua se Revise la secci6n "Mantenimiento" condensa dentro del tanque de aire. Si no se drena, ella de las p_ginas precedentes y ejecute el mantenimiento programado corroer_ debiHtando...
  • Page 47 Riesgo de Operaci6n Insegura: La unidad arranca autom&tieamente cuando est_ enehufada. Amhaeer el mantenimiento, el operador puede quedar e×puesto a fuentes de corriente de aire comprimido o a piezas mevibles. Antes de intentar hacer reparaciones, desconectar eRcompresor del tomacorriente, drenar la presi6n de aire del tanque y esperar a que el compresor se enfrie.
  • Page 48 PROBLEMA CAUSA CORRECCION Si hubiese una caida excesiva La lectura de la Es normal que ocurra algOn de presi6n durante el uso del presi6n sobre un descenso en la presi6n. accesorio, ajuste el regulador de man6metro acuerdo a las instrucciones de la viene equipado secci6n "Operaci6n".
  • Page 49 PROBLEMA CAUSA CORRECCION El motor no Deje enfriar el motor y el El interrupter de protecci6n funciona. obrecarga del motor se ha interruptor de sobrecarga se abierto. reajustar9 autom_ticamente. El motor arrancar9 autom_ticamente La presi6n del tanque excede cuando la presi6n del tanque caiga la presi6n de "corte m_ximo"...
  • Page 50 A09710 50-SP...
  • Page 51: Repair Protection Agreements

    Repair Protection Agreements Reparaciones Congratulations on making a smart Felicitac/ones pot hacer una compra purchase. Your new Craftsman C_) p roduct inteligente. Su nueva unidad Craftsman ® esta is designed and manufactured for years diseffada y fabricada para afros de operaci6n of dependable operation.