Friedrich Twintemp YQ07 Operating Manual page 3

Hide thumbs Also See for Twintemp YQ07:
Table of Contents

Advertisement

Available languages

Available languages

920-003-I0 (4-05)
Testthe powercord
All Friedrich room air conditioners are shipped from the
factory with a Leakage Current Detection Interrupter (LCDI)
equipped power cord. The LCDI de/ice meets the UL and
NEC requirements
for cord connected
air conditioners
effective August 2004.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET (See Figure 2).
3. Press TEST (listen for click; Reset button trips and
pops out).
4. Press and release RESET (listen for click; Reset button
latches and remains in). The power supply cord is ready
for operation.
NOTE:
LCDI device is not intended
to be used as a
switch.
Once plugged in the unit will operate normally without the
need to reset the LCDI device.
If the device l_ailsto trip when tested or if the power supply cord
is damaged it must be replaced with a new supply cord from
the manul:acturer. We recommend you contact our Technical
Assistance
Line at (800) 541-6645 ext. 662. To expedite
service, please have your model and serial number available.
MODEL
PLUG FACE
CIRCUIT RATING OR
TIME DELAY FUSE
AMP
VOLT
15
125
20
250
30
250
NEMA NO.
YQ07.EQ08.YS09
5-15P
@
YS13.ES12.
ES16
6-20P
@
YM18oyL24oEMtSoEM24oEL25oEL36
6-30P
@
--
Reset Button
Figure
1
Figure
2
Forthe bestcooling performance & highestenergy efficiency
Keep the filter clean
Make sure that your air conditioner is always in top per-
forming condition by cleaning the filter regularly. Instruc-
tions for removing and cleaning the filter can be found on
page 5 and 6.
Providegoodairflow
Make sure that the airflow to and from the unit is clear.
Your air conditioner puts the conditioned
air out at the top
of the unit, and takes in unconditioned
air at the bottom.
Airflow is critical to good operation. It is just as important
on the outside of the building that the airflow around the
unit exterior is not blocked.
Insulation
Good insulation will be a big help in maintaining desirable
comfort levels. Doors should have weather stripping. Be
sure to caulk around doors and windows.
Properinstallationof sealgasket
Make sure the seal gasket has been installed properly to
minimize noise and improve efficiency. If the seal gasket
has not been installed,
please refer to your installation
instruction manual.
Unit placement
If your air conditioner can be placed in a window or a wall
that is shaded by a tree or another building, the unit will
operate even more efficiently. Using drapes or blinds on
the sunny side of the dwelling will also add to your unit's
efficiency.