Verifying The Installation; Upgrading - HP XP20000/XP24000 Administrator's Manual

Hp storageworks p9000 virtualization adapter administrator guide (5697-0680, october 2010)
Hide thumbs Also See for XP20000/XP24000:
Table of Contents

Advertisement

3.
Restart the SRM service using the vmware-dr command:
C:\>net STOP vmware-dr
The VMware Site Recovery Manager Service service is stopping.
The VMware Site Recovery Manager Service service was stopped
successfully.
C:\>net START vmware-dr
The VMware Site Recovery Manager Service service is starting.
The VMware Site Recovery Manager Service service was started
successfully.
4.
Set any environment variables. See
If you change environment variables, restart the SRM service. See step 3.

Verifying the installation

After a new installation or update, verify the version information by issuing the help command:
For Windows:
%HORCMROOT%\HORCM\etc>rmsra −h
For UNIX:
/HORCM/usr/bin/rmsra −h
The version is displayed as xx.xx.xx in the example below:
Ver&Rev: xx.xx.xx
Usage: rmsra
[-h]
[-XMLSTDOUT]
[-XMLSTDERR]
[-auto]
[sralog=path_name]
[loglvl=value]
[timeout=value]
[testMU=value]

Upgrading

Upgrade the XP or P9000 Virtualization Adapter using an executable (rmxpsra.exe).
You must upgrade the product on both the local site SRM server (protected site) and the remote site
SRM server (recovery site).
28
Installing and removing the P9000 Virtualization Adapter
"Environment
variables" on page 22.
Help/Usage
Change XML_output to STDOUT
Change XML_output to STDERR
Start HORCM automatically.
Change STDERR_output to path_name.
Change logging level to ( quiet/error/warning/info/
verbose/trivia ) on STDERR.
Specify timeout_value( in sec ) for UR/Async.
Specify MU# using for failover testing.