Figure 8 horcmX.conf on secondary site
.
NOTE:
For failover testing on Continuous Access and Continuous Access Journal S-VOL:
•
If the Business Copy licence is not installed, SRM requires that SplitReplication is set to true.
•
If the Business Copy licence is installed, SRM requires that SplitReplication is set to true and the
MU number except 0 is specified as $RMSRATMU variable.
•
Establish communication between the HORCM of the primary site and the HORCM of the recovery
site.
•
For non-stop testing of an application, Continuous Access Synchronous CTG or Continuous Access
Journal volumes must be used.
Snapshot for failover testing
The point-in-time copy for failover testing must be created as volume using point-in-time-split (this
capability is supported only for Business Copy and Snapshot).
C:\HORCM\etc> paircreate –g <group> -m grp -fq quick -pid <snapshotpool>
Required LUN ID
VMware ESX Server supports NAA version 6 information in Page 83 SCSI inquiry as UUID.
ESX Server, Datastore, and SRM recognize a LUN using LUN WWN returned by the disk array.
Therefore, the P9000 Virtualization Adapter returns the LUN WWN, matching the datastore regardless
of Multi-Path I/O (MPIO).
The device identification must include NAA version 6 information in Page 83 SCSI.
P9000 Virtualization Adapter Administrator Guide