Figure 8 horcmX.conf on secondary site
.
NOTE:
For failover testing on Continuous Access and Continuous Access Journal S-VOL:
If the Business Copy licence is not installed, SRM requires that SplitReplication is set to true.
If the Business Copy licence is installed, SRM requires that SplitReplication is set to true and the
MU number except 0 is specified as $RMSRATMU variable.
Establish communication between the HORCM of the primary site and the HORCM of the recovery
site.
For non-stop testing of an application, Continuous Access Synchronous CTG or Continuous Access
Journal volumes must be used.
Snapshot for failover testing
The point-in-time copy for failover testing must be created as volume using point-in-time-split (this
capability is supported only for Business Copy and Snapshot).
C:\HORCM\etc> paircreate –g <group> -m grp -fq quick -pid <snapshotpool>
Required LUN ID
VMware ESX Server supports NAA version 6 information in Page 83 SCSI inquiry as UUID.
ESX Server, Datastore, and SRM recognize a LUN using LUN WWN returned by the disk array.
Therefore, the P9000 Virtualization Adapter returns the LUN WWN, matching the datastore regardless
of Multi-Path I/O (MPIO).
The device identification must include NAA version 6 information in Page 83 SCSI.