sw Traps
swFault
Enterprise
Variables
Description
swSensorScn (Obsoleted by swFabricWatchTrap)
Enterprise
Variables
Description
FC Switch MIB Object Types
sw
swDiagResult
A 1 (swFault) is generated whenever the diagnostics detect a fault with the
switch.
#TYPE
#SUMMARY
#ARGUMENTS
#SEVERITY
#TIMEINDEX
#STATE
sw
swSensorStatus, swSensorIndex, swSensorType, swSensorValue,
swSensorInfo
A 2 (swSensorScn) is generated whenever an environment sensor changes
its operational state. For example, a fan stops working. The VarBind in the
Trap Data Unit contains the corresponding instance of the sensor status,
sensor index, sensor type, sensor value (reading), and sensor information.
Switch is faulty.
Faulty reason: %d
0
Critical
1
Non-operational
341