Dell PowerEdge T300 Series Hardware Owner's Manual page 38

Hardware owner's manual (pdf)
Hide thumbs Also See for PowerEdge T300 Series:
Table of Contents

Advertisement

Table 1-6. System Messages (continued)
Message
Warning: A fatal
error has caused
system reset!
Please check the
system event log!
Warning! No micro
code update loaded
for processor n
Warning! Detected
missing RAID
hardware for the
embedded RAID
subsystem.
Warning! Detected
mode change from
SCSI to RAID on
channel x of the
embedded RAID
subsystem.
Warning! Detected
mode change from
RAID to SCSI on
channel n of the
embedded RAID
subsystem.
Warning! Embedded
RAID firmware is
not present.
Warning! Embedded
RAID error!
38
About Your System
Causes
A fatal system error
occurred and caused the
system to reboot.
A microcode update
failed.
RAID key or RAID DIMM
missing when system is in
RAID mode.
The embedded RAID
subsystem configuration
has changed in System
Setup.
The embedded RAID
subsystem configuration
has changed in System
Setup.
The embedded RAID
firmware does not
respond.
The embedded RAID
firmware responds with an
error.
Corrective Actions
Check the SEL for
information that was logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
Your System" on page 133 for
any faulty components
specified in the SEL.
Update the BIOS firmware.
If the problem persists, see
"Getting Help" on page 175.
Information only.
See "Using the System Setup
Program" on page 42.
See "Using the System Setup
Program" on page 42.
See "Using the System Setup
Program" on page 42.
See "Using the System Setup
Program" on page 42.

Advertisement

Table of Contents
loading

Table of Contents