Valve Tray Replacement - Regency Liberty L676-NG1 Owners & Installation Manual

Table of Contents

Advertisement

MAINTENANCE
1) Shut off the gas supply to the unit.
2) Remove the right side mesh by gathering the
mesh together and lifting the curved end of
the rod up and out of the bracket located on
the top right of the glass frame.
Now slide the straight end of the rod out from
the bracket located on the middle inside top
of the outer shell. Repeat for left side.
Right Side Rod with Screen Removed
3) Remove the front cover plate by lifting up
off of the pins on the left and right side of
the fi rebox.
Front Cover Plate
Right Side Pin Shown
42

VALVE TRAY REPLACEMENT

4) Remove the glass door.
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
Latch Location
Latch
b. Swing the door out from the top and release
the hinge on the left side of the door and
lift out.
Hinge
c. Place the door on a soft surface to prevent
scratching.
5) Remove the log set.
6) Remove the burner orifi ce cover plate from
the log tray by undoing the 2 screws.
7) Remove the brick panels.
8) Remove the grate by undoing the 3
screws.
Grate
9) Remove the burner tube by removing the 2
screws.
Door
Burner Tube
10) Remove the rear log stand by removing
the 4 screws.
Rear Log Stand
Regency
®
L676-1 Direct Vent Gas Fireplace
Burner Orifi ce Cover Plate

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liberty l676-lp1Liberty l676-1

Table of Contents