Log Set Installation - Regency Liberty L676-NG1 Owners & Installation Manual

Table of Contents

Advertisement

INSTALLATION
Installation of Brick Panels must be completed before installing the log set.
Read the instructions below carefully and refer to the images. If the
logs are broken do not use the unit until they are replaced. Broken
logs can interfere with pilot operation.
Improper positioning of the logs may create carbon build-up and can
alter the unit's performance which is not covered under warranty.
Log kit # 522-930 contains the following pieces:
Part #
Description
A
Log Rear
B
Log Front Left
C
Log Front Right
D
Log Rear Top Left
E
Log Rear Top Center
F
Log Cross Right
902-179
Vermiculite
902-153
Rock Wool
946-669
Platinum Embers
B
D
The reference numbers (i.e. A) are molded
into the rear of each log.
1) Carefully remove the logs from it's packaging and unwrap them. The
logs are fragile, handle with care - do not force into position.
32

LOG SET INSTALLATION

(supplied with packaged manual)
F
C
E
A
2) Spread vermiculite along the base of the fi rebox.
Vermiculite
3) Place rock wool inbetween the burner tubes and cover the front burner
tube by pulling rock wool apart and loosely place as shown. Also
place a small amount of rock wool between the log support and the
rear of the burner tube. DO NOT block the air inlet or buner ports.
4) Separate platinum embers and place over top of the rock wool on
the front burner tube. Avoid stacking platinum embers.
Regency
®
L676-1 Direct Vent Gas Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liberty l676-lp1Liberty l676-1

Table of Contents