Valve Tray Replacement - Regency Greenfire GF900C Owners & Installation Manual

Hide thumbs Also See for Greenfire GF900C:
Table of Contents

Advertisement

maintenance

VALVE TRAY REPLACEMENT

PRIOR TO SERVICING THE FAN, ENSURE UNIT HAS COOLED TO
ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS
SUPPLY IT TURNED OFF.
1. Remove faceplate, inner frame, glass door, and inner panels - see
instructions in this manual.
2. Remove crystals and stones if installed.
3. Remove burner tray by removing 3 screws shown in Diagram 1.
Diagram 1 - Burner Tray Screw Locations
4. Remove burner by removing 2 screws in locations shown below.
Diagram 2 - Burner Screw Locations
5. Remove air deflector by removing 3 screws in locations shown below.
Diagram 3 - Air Deflector Screw Locations
54
6. Remove burner by removing 14 screws in locations shown below.
Diagram 4 - Valve Tray Screw Locations
7. Lift out valve tray.
Diagram 5 - Valve Tray Removal
8.
Replace valve tray and reverse steps.
Regency GF900C-2 Gas Fireplace