The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue fl ame or
close for a more yellow fl ame.
In order to adjust the aeration, the logs, grate
and burner will need to be removed to be able
to access the shutters.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
Regency
®
L676-1 Direct Vent Gas Fireplace
AERATION ADJUSTMENT
Minimum Air Shutter Opening:
NG
1/8"
LP
5/16"
WIRING DIAGRAM
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.
INSTALLATION
CAUTION: Carbon will be produced if air shutter
is tightly closed.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
NOTE: The #8 ground lug is located on
the outer left side of the unit.