SAFETY LABEL

This is a copy of the label that accompanies
each L676-NG1 and L676-LP1 Direct Vent
Gas Fireplace. We have printed a copy of the
contents here for your review. The safety label
is located on the left hand side of the unit behind
the mesh screen.
NOTE: Regency
units are constantly being
®
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
4
Regency
®
L676-1 Direct Vent Gas Fireplace