Removing The Hp Sensor; Removing The Pw Sensor Assembly - Epson TM-FX2180 Service Manual

Epson 9 pin impact dot printer service manual
Table of Contents

Advertisement

EPSON FX-2180 Service Manual

4.2.4 Removing the HP Sensor

Remove the printer cover, ribbon cartridge, front edge guide, and front
1.
cover. (See section 4.2.1.)
Disconnect the connector cable for the HP sensor.
2.
IMPORTANT
Note the orientation of the HP sensor so you can
reinstall it the same way. See Figure 4-8.
Remove the HP sensor from the front paper entrance by pushing up
3.
and releasing the two clips at the bottom of the HP sensor.
2 clips securing the HP sensor
Figure 4-8. Removing the HP Sensor

4.2.5 Removing the PW Sensor Assembly

Remove the printer cover and ribbon cartridge. (See section 4.2.1.)
1.
Remove the print head. (See section 4.2.3.)
2.
Remove the CB screw (2.5
3.
mask holder.
Release the three clips on the CR cover that secure it to the bottom of
4.
the CR assembly. Then lift the cover slightly.
Remove the FFC from the PW sensor connector on the CR cover.
5.
Remove the PW sensor assembly along with the CR cover by pushing
6.
and releasing the clip for the CR cover, as shown in Figure 4-9.
Figure 4-9. Removing the PW Sensor Assembly
Chapter 4 Disassembly and Assembly
5) securing the PW sensor to the ribbon
4-8

Advertisement