EPSON FX-2180 Service Manual
Program : J******
9 pins
VR 0 = 0
[
Main MENU
(1) Bi-d Adjust
>(2) FF paper
(3) A3 Cut sheet
(4) A4 1P Cut sheet
(5) A4 6P Cut sheet
Figure 5-14. Main Menu
Select one of the Check programs (selections 2 through 6) depending
6.
on the paper loaded in the printer. Run the Check program to write the
selected factory settings to the EEPROM and print several check
patterns.
To exit the program, press Esc until you return to the DOS prompt.
7.

5.2.4 TPE Level Reset

This section describes how to reset the TPE (top paper end) level (value).
Table 5-1 lists when you need to reset the TPE level. For example, if you
do not perform this adjustment after you replace the PW sensor assembly,
the printer does not recognize that the PW sensor has been replaced, and
the ability of the new sensor to operate properly is limited. You can perform
this procedure using the Settings diskette only.
IMPORTANT
After you perform the TPE level reset adjustment,
the printer automatically prints the reset value for
the TPE level. Check that the reset value is FF.
Make sure the PC is turned off. Insert the Settings diskette into drive A
1.
of the PC and turn on the PC.
2.
Exit Windows and go to the DOS prompt.
Setting : *****
VR 1 = 0
VR 2 = 0
]
(6) Envelope
(7) ---- N/A ----
(8) -- SUB MENU
At the DOS prompt, type GWBASIC J10a72v.bas and press Enter.
3.
You see the Printer Select menu.
Program : J******
9 pins
VR 0 = 0
[
Printer select
> (1) 9 pins
(2) 24 pins
Figure 5-15. Printer Select Menu
Use the
or
key to highlight 9 pins and then press Enter. You see
4.
the Setting File menu.
Program : J******
9 pins
VR 0 = 0
[
Setting File
> (1) DEFSTD
(2) EURSTD
(3) NLSP
(4) ITALIC
(5) RUSSIAN
Figure 5-16. Setting File Menu
Use the
or
key to highlight the factory setting for the printer's
5.
destination and press Enter. Refer to Table 5-3 for destination settings.
Chapter 5 Adjustments
Setting : *****
VR 1 = 0
VR 2 = 0
]
Setting : ******
VR 1 = 0
VR 2 = 0
]
5-8