Voltage Recovery Timing Specifications; Table 74. Transient Load Requirements - Intel SE7505VB2 Specification

Product specification
Hide thumbs Also See for SE7505VB2:
Table of Contents

Advertisement

Intel® Server Board SE7505VB2
12.2.2

Voltage Recovery Timing Specifications

The power supply must conform to the following specifications for voltage recovery timing under
load changes:
Voltage shall remain within +/- 5% of the nominal set voltage on the +5 V, +12 V, 3.3 V, -
5 V and -12 V output, during instantaneous changes in load shown in the following table.
Voltage regulation limits shall be maintained over the entire AC input range and any
steady state temperature and operating conditions specified.
Voltages shall be stable as determined by bode plot and transient response. The
combined error of peak overshoot, set point, regulation, and undershoot voltage shall be
less than or equal to +/-5% of the output voltage setting. The transient response
measurements shall be made with a load changing repetition rate of 50 Hz to 5 kHz. The
load slew rate shall not be greater than 0.2 A /µs.
Output
Step Load
Size
+3.3 V
4.8 A
+5 V
3.0 A
+12 V
10.4 A
+5 VSB
500 mA
-12 V
325 mA
Revision 1.2

Table 74. Transient Load Requirements

Starting Level
30Min. Load
Min. load + 4.8 A and step up to max. load
Min. load + 3.0 A and step up to max. load
30Min. Load
Min. Load
Min. load + 10.4 A and step up to max. load
Min. Load
Min. load + 500 mA and step up to max. load
Min load +325 mA and step up to max. load
Min. Load
Intel part number C32194-002
Finishing Level
Power Information
Slew Rate
0.50 A/µs
0.50 A/µs
0.50 A/µs
0.50 A/µs
0.50 A/µs
99

Advertisement

Table of Contents
loading

Table of Contents