Removing A Memory Module - Lenovo ThinkServer TD200x Installation And User Manual

(english) installation and user guide
Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

6. Close the bezel (see "Closing the bezel" on page 98).

Removing a memory module

To remove a dual inline memory module (DIMM), do the following:
10. Using your fingers, lift the DIMM out of the DIMM connector.
11. If you are instructed to return the DIMM, follow all packaging instructions, and
84
ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide
1
DIMM
2
Retaining clip
1. Read the safety information that begins on page vii and "Handling
static-sensitive devices" on page 39.
2. Turn off the server and peripheral devices, and disconnect the power cords
and all external cables.
3. Turn the server on its side so that it is lying flat, with the cover facing up.
4. Unlock and remove the left-side cover (see "Removing the left-side cover" on
page 42).
5. Remove the hot-swap power supply or power supplies from the power-supply
cage (see "Removing a hot-swap power supply" on page 63).
6. Rotate the power-supply cage to its open position (see "Opening the
power-supply cage" on page 47).
7. Remove the air baffle (see "Removing the air baffle" on page 58).
8. Locate the DIMM connectors on the system board (see "System-board internal
connectors" on page 25).
Attention:
To avoid breaking the retaining clips or damaging the DIMM
connectors, handle the clips gently.
9. Move the DIMM retaining clips on the side of the DIMM connector to the open
position by pressing the retaining clips away from the center of the DIMM
connector.
use any packaging materials for shipping that are supplied to you.

Advertisement

Table of Contents
loading

Table of Contents