12.3

Mounting the Power Supply Unit

Caution – Do not forcibly push the power supply unit into the slot. Forcibly
pushing the component in a slot may damage the component or the server.
1. Align the top of the unit with the top of the slot.
Doing so prevents the bottom of the slot from cutting the power cord at the
bottom of the unit.
2. Set the handle so that it is perpendicular to the server, and then push the
power supply unit into the slot.
3. Insert the power supply unit until it reaches the predetermined position, and
then return the handle to its original position.
4. Secure the power cord with the cord clamp.
5. Complete the replacefru command which has been executed in the XSCF
command prompt. For details, see
Replacement (Power supply unit/Fan unit)" on page
12.4

Reassembling the Server

From the XSCF Shell prompt, use the showhardconf command to verify that the
new power supply unit has been installed.
XSCF> showhardconf
For details, see
unit/Fan unit)" on page
Section 4.4.2, "Verifying the Hardware Operation (Power supply
4-10.
Section 4.4.1, "FRU Removal and
4-8.
Chapter 12
Power Supply Unit Replacement
12-5